Catalog Number CAT6
Device Problems Device Damaged Prior to Use (2284); Material Deformation (2976)
Patient Problem No Patient Involvement (2645)
Event Date 05/10/2019
Event Type  malfunction  
Manufacturer Narrative
The device has been returned and the investigation results are pending.A follow up mdr will be submitted upon completion of the device investigation.
 
Event Description
During preparation for a thrombectomy procedure, the hospital staff noticed that the tip of an indigo system aspiration catheter 6 (cat6) appeared crushed before being taking out of the package.The damaged cat6 was found prior to use and, therefore, was not used in the procedure.The procedure was completed using a new cat6.
 
Manufacturer Narrative
Results: the returned cat6 was kinked at approximately 45.0 cm, 128.0 cm, 131.0 cm and 132.0 cm from the hub.The device was ovalized at approximately 134.0 cm from the hub.Conclusions: evaluation of the returned cat6 revealed an ovalization on the distal tip.If the device is forcefully gripped or pinched during preparation for a procedure, damage such as an ovalization may occur.Further investigation revealed kinks along the length of the returned cat6.These kinks were likely incidental to the complaint and may have occurred during packaging for return to penumbra.Penumbra catheters are inspected during in-process inspection and during quality inspection after manufacturing.The manufacturing records for this lot were reviewed and did not reveal any outstanding discrepancies, design, or quality concerns.H3 other text : placeholder.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INDIGO SYSTEM ASPIRATION CATHETER 6
Type of Device
DXE
Manufacturer (Section D)
PENUMBRA, INC.
one penumbra place
alameda CA 94502
MDR Report Key8698186
MDR Text Key148011430
Report Number3005168196-2019-01155
Device Sequence Number1
Product Code DXE
UDI-Device Identifier00814548016245
UDI-Public00814548016245
Combination Product (y/n)Y
PMA/PMN Number
K160533
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 01/01/2005,05/15/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date02/19/2022
Device Catalogue NumberCAT6
Device Lot NumberF88639
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/21/2019
Was the Report Sent to FDA? Yes
Date Report Sent to FDA01/01/2005
Date Report to Manufacturer01/10/2005
Initial Date Manufacturer Received 05/15/2019
Initial Date FDA Received06/13/2019
Supplement Dates Manufacturer Received07/09/2019
Supplement Dates FDA Received07/24/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-