MAUDE Adverse Event Report: PHILIPS MEDICAL SYSTEMS DMC GMBH COMBIDIAGNOST R90; TABLE, RADIOLOGIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

PHILIPS MEDICAL SYSTEMS DMC GMBH COMBIDIAGNOST R90; TABLE, RADIOLOGIC Back to Search Results
Model Number 709030
Device Problem Smoking (1585)
Patient Problem No Patient Involvement (2645)
Event Type  malfunction  
Manufacturer Narrative
Int.Ref.(b)(4).The investigation is still ongoing on this event.When the investigation is completed a follow-up report will be sent to the fda.
 
Event Description
The customer complained about the system power distribution unit (in short named spdu) produced a significant amount of smoke.Hospitals smoke sensor was activated and the fire department was involved.No patient involvement.
 
Manufacturer Narrative
Int.Ref.(b)(4).The combi diagnost r90 is a digital motorized remote controlled x ray system used for fluoroscopic and radiographic imaging.The system power distribution unit (spdu) is the main power supply for the complete system without the x ray generator.It contains a three phase transformer with a power rate of about 7kva (kilo volt ampere).Inside even of the three coils a thermo switch is installed to prevent overheating.Philips field service engineer investigated on the site and found the transformer burned and the thermo switches were without function.The thermo switches were accidentally deactivated via a pre-installed short wire (bridge) at the connection terminals at the spdu during manufacturing.The 3 phase main circuit breaker inside the spdu was found released.That lead to that the mains was disconnected to the transformer before the firefighter disconnected the whole room.Philips field service engineer replaced the transformer and activated the thermo switch by removing the short wire.After this repair the system works as specified again.A corrective action preventive action (capa) was initiated and resulted in a field safety corrective action (fco 70900045 / 70900048).After implementation of the field safety corrective action the risk is estimated as acceptable risk.This issue is further monitored and trended.Submission of a report does not constitute an admission that medical personnel, user facility, importer, distributor, manufacturer, or product caused or contributed to the event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
COMBIDIAGNOST R90
Type of Device
TABLE, RADIOLOGIC
Manufacturer (Section D)
PHILIPS MEDICAL SYSTEMS DMC GMBH
roentgenstr. 24
hamburg 22335
GM  22335
MDR Report Key8883839
MDR Text Key154120695
Report Number3003768251-2019-00012
Device Sequence Number1
Product Code JAA
UDI-Device Identifier00884838076747
UDI-Public(01)00884838076747
Combination Product (y/n)N
PMA/PMN Number
K163210
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Remedial Action Recall
Type of Report Initial,Followup
Report Date 07/24/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number709030
Device Catalogue Number709030
Was Device Available for Evaluation? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 07/24/2019
Initial Date FDA Received08/12/2019
Supplement Dates Manufacturer Received07/24/2019
Supplement Dates FDA Received10/08/2020
Is This a Reprocessed and Reused Single-Use Device? No
Removal/Correction NumberZ-1328-2020
Patient Sequence Number1
-
-