WRIGHTS LANE SYNTHES USA PRODUCTS LLC UNK - CONSTRUCTS: VEPTR; PROSTHESIS, RIB REPLACEMENT
|
Back to Search Results |
|
Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problem
Bone Fracture(s) (1870)
|
Event Type
Injury
|
Manufacturer Narrative
|
This report is for an unknown veptr construct/unknown lot.Part and lot number are unknown; udi number is unknown.Complainant part is not expected to be returned for manufacturer review/investigation.Without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.(b)(4).
|
|
Event Description
|
This report is being filed after the review of the following journal article: parnell, s.E.Et al (2015), vertical expandable prosthetic titanium rib (veptr): a review of indications, normal radiographic appearance and complications, pediatric radiology, vol.45 (4), pages 606-616 (usa).The aim of this study is to reviews the clinical indications and strategies for the use of the veptr device, imaging modalities that may be used in the evaluation and management of patients with thoracic insufficiency syndrome and familiarizes the reader with the types of complications that can occur with emphasis on the radiographic findings that are seen with these complications.An unknown number of patients were included in the study.Surgery was performed using vertical expandable prosthetic titanium rib (veptr; synthes, west chester, pa).The following complications were reported: an 11-year-old boy had right posterior rib fracture adjacent to the superior cradle of the veptr device.A 6-year-old girl had migration of the superior rib cradle and erosion through the ribs.An 8-year-old girl had inferolateral dislodgement of the s-hook and increased thoracolumbar levoscoliosis.An 8-year-old girl had erosion of hardware (pelvic hook) through the skin with persistent serosanguinous drainage from the wound, raising question of infection.An 8-year-old girl had abnormal migration of the lumbar hook into the spinal canal at the lumbosacral junction causing soft-tissue damage and radiculopathy.A 5-year-old boy had migration of the superior cradle over time indicating dislodgement of the cradle from the original rib anchors.A 10-year-old girl had a fracture (broken hardware) of the inferior portion of the rib sleeve of a hybrid veptr device.This report is for an unknown synthes veptr construct.This is report 1 of 7 for (b)(4).
|
|
Manufacturer Narrative
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Search Alerts/Recalls
|
|
|