Catalog Number 227455000
Device Problem Break (1069)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 01/01/2019
Event Type  malfunction  
Manufacturer Narrative
Product complaint # (b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
Screw holding forceps broke whilst in use, inserting the acetabular screw.There was minimal force used, and the instrument only broke into 2 pieces which were retrieved.
 
Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provision of 21 cfr, part 803.The report may be based on the information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the added:device manufactured date.Product complaint (b)(4).Investigation summary: the product was returned to the depuy australia engineering dept where it was assessed by the engineering technician.The product was deemed to have broken due to wear and tear.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Corrective action was not indicated.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
QUICKSET SCR HOLDING FORCEPS
Type of Device
HIP INSTRUMENTS : INSERTION DEVICES
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
MDR Report Key8951319
MDR Text Key163339250
Report Number1818910-2019-102696
Device Sequence Number1
Product Code GEN
UDI-Device Identifier10603295109303
UDI-Public10603295109303
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 08/12/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number227455000
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 08/12/2019
Initial Date FDA Received08/30/2019
Supplement Dates Manufacturer Received10/30/2019
Supplement Dates FDA Received10/31/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Age66 YR
-
-