PHILIPS HEALTHCARE ALLURA XPER FD10; SYSTEM, X-RAY, ANGIOGRAPHIC Back to Search Results
Model Number 722003
Device Problem Output Problem (3005)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
The investigation is still ongoing on this event.When the investigation is completed a follow-up report will be sent to the fda.
 
Event Description
It has been reported to philips that fluoroscopy became unavailable during a pacemaker implantation procedure.The physician was not able to view the wires that were already in the heart.The operators were able to finish the case successfully.No patient injury has been reported to philips.Philips has started an investigation of this complaint.
 
Manufacturer Narrative
Philips has investigated this complaint.Once fluoroscopy became unavailable, the operator paused the case to bring in a mobile x-ray system.There was a delay of approximately 10 minutes while the patient was under general anesthesia.Philips performed trouble shooting of the system on site and determined that the flat detector was defective.The flat detector was replaced after which the system was returned to use in good working order.Based on trending analysis there is no negative trend with the replacement rate for the flat detector.Consequently, philips has closed this complaint.Submission of a report does not constitute an admission that medical personnel, user facility, importer, distributor, manufacturer, or product caused or contributed to the event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ALLURA XPER FD10
Type of Device
SYSTEM, X-RAY, ANGIOGRAPHIC
Manufacturer (Section D)
PHILIPS HEALTHCARE
veenpluis 4-6
p.o. box 10.000
best 5680 DA
NL  5680 DA
MDR Report Key9220434
MDR Text Key168809326
Report Number3003768277-2019-00083
Device Sequence Number1
Product Code IZI
Combination Product (y/n)N
PMA/PMN Number
K041949
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 10/02/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number722003
Device Catalogue Number722003
Was Device Available for Evaluation? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 10/02/2019
Initial Date FDA Received10/22/2019
Supplement Dates Manufacturer Received10/02/2019
Supplement Dates FDA Received01/10/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-