• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: DEPUY MITEK LLC US UNKNOWN RIGIDFIX CROSS PIN; SOFT-TISSUE ANCHOR, BIOABSORBABLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DEPUY MITEK LLC US UNKNOWN RIGIDFIX CROSS PIN; SOFT-TISSUE ANCHOR, BIOABSORBABLE Back to Search Results
Catalog Number UNK RIGIDFIX
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Tissue Damage (2104); Not Applicable (3189)
Event Date 02/25/2010
Event Type  Injury  
Manufacturer Narrative
This report is for an unknown.Part and lot number are unknown.Without the specific part number; the udi number and 510-k number is unknown.Complainant part is not expected to be returned for manufacturer review/investigation.Concomitant medical products: unknown.Without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.(b)(4).
 
Event Description
This is report 1 of 2 for the same event.This report is being filed after the review of the following journal article: lee, sh., et al (2010), combined reconstruction for posterolateral rotatory instability with anterior cruciate ligament injuries of the knee, knee surgery sports traumatology arthroscopy, vol.18, pages 1219-1225 (korea, south).Doi: 10.1007/s00167-010-1078-4.The study emphasizes on evaluating the clinical outcomes and technical aspects of combined acl-pcl reconstruction using hamstring tendon autografts.The patients evaluated on course of this study: from 2002 to 2007, a total of 44 knees (41 males and 3 females), with a median age of 29 years (range 16-53) at the time of surgery, who underwent a combined reconstruction for posterolateral rotatory instability with anterior cruciate ligament injuries of the knee were included in the study.The article describes the following procedure: a combined reconstruction for posterolateral rotatory instability with anterior cruciate ligament injuries of the knee.The devices involved were: rigidfixtm femoral fixation and mitek intrafixtm tibial fixation (mitek product, (b)(4), usa), femoral fixation system and bioabsorbable interference screw.Complications mentioned in the article: 2 patients had knee joint stiffness; 1 of whom was subjected to an adhesiolysis performed arthroscopically 6 months after surgery; on the final follow-up, both patients could not squat fully.1 patient was subjected to an arthroscopic examination because of a hemarthrosis and loss of motion due to reinjury 18 months after surgery; result revealed a hematoma due to a partial rupture of the acl graft tendon and a debridement was performed.2 patients developed an infection of the knee joint that healed after arthroscopic irrigation and debridement without graft removal.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN RIGIDFIX CROSS PIN
Type of Device
SOFT-TISSUE ANCHOR, BIOABSORBABLE
Manufacturer (Section D)
DEPUY MITEK LLC US
325 paramount drive
raynham MA 02767
Manufacturer Contact
kara ditty-bovard
325 paramount drive
raynham, MA 02767
5089776860
MDR Report Key9255726
MDR Text Key183567545
Report Number1221934-2019-59329
Device Sequence Number1
Product Code HTY
Combination Product (y/n)N
Reporter Country CodeKS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,literature
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 10/25/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue NumberUNK RIGIDFIX
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 10/25/2019
Initial Date FDA Received10/30/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-