SMITH & NEPHEW MEDICAL LTD. IV3000 1 HAND 10X12CM CTN 50; TAPE AND BANDAGE, ADHESIVE Back to Search Results
Catalog Number 4008
Device Problem Positioning Problem (3009)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 07/26/2019
Event Type  malfunction  
Event Description
It was reported that the film was falling off when applied.A new one was used to complete the treatment, no delay or patient harm reported.
 
Manufacturer Narrative
We have now concluded our investigation for the complaint received.A review of the associated batch manufacturing records did not identify any issue at the point of manufacture which may have caused or contributed to the issue highlighted by the complainant.In addition it can be confirmed that all finished product specification testing was satisfied at the point of release.A complaints history review was carried out using the lot and part numbers provided, there have been 4 further complaints reported with this issue in the past four years.As no samples were returned, a functional evaluation was not possible.Low adhesion may be caused by adhesion levels of the raw material used to make the film of this dressing.There are various controls in place during the manufacturing process of both the raw material and the dressing to identify when the adhesion is not in acceptable range, as per the product specification.There are also regular tests carried out to monitor the finished product.It was confirmed that the issue was experienced during / immediately after application of the dressing.The skin site in which the dressing is to be placed must be thoroughly dry.As with all adhesive products, the skin must be appropriately prepared to ensure adhesive performance is not compromised.We have not been able to identify a definitive root cause on this occasion.No further actions by smith and nephew are deemed necessary at this stage.However, we will continue to monitor for any adverse trends relating to this product range.Smith and nephew acknowledge customer concern and are continually investigating ways to develop and improve our products.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
IV3000 1 HAND 10X12CM CTN 50
Type of Device
TAPE AND BANDAGE, ADHESIVE
Manufacturer (Section D)
SMITH & NEPHEW MEDICAL LTD.
101 hessle road
hull HU3 2 BN
UK  HU3 2BN
MDR Report Key9410825
MDR Text Key169088942
Report Number8043484-2019-00881
Device Sequence Number1
Product Code KGX
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 01/10/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number4008
Device Lot Number1802
Initial Date Manufacturer Received 11/05/2019
Initial Date FDA Received12/04/2019
Supplement Dates Manufacturer Received11/05/2019
Supplement Dates FDA Received01/10/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-