• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: STRYKER NEUROVASCULAR-UTAH-SALT LAKE CITY TREVO 14 PRO MICROCATHETER; CATHETER, INTRAVASCULAR, DIAGNOSTIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER NEUROVASCULAR-UTAH-SALT LAKE CITY TREVO 14 PRO MICROCATHETER; CATHETER, INTRAVASCULAR, DIAGNOSTIC Back to Search Results
Model Number 90231
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Intracranial Hemorrhage (1891); High Blood Pressure/ Hypertension (1908)
Event Date 11/12/2019
Event Type  Injury  
Manufacturer Narrative
This is the 4th of 7 reports.Subject device is not available.
 
Event Description
It was reported that that the physician was performing a stent assisted-coiling procedure of a small, un-ruptured, right internal carotid artery (ica) ophthalmic aneurysm in a relatively dysplastic vessel.The stent was successfully deployed across the aneurysm neck using jailed technique.The physician attempted to deploy a first coil, but the coil appeared to be too big and long for the aneurysm, as the coil kept herniating downward into the parent vessel.Prior to detaching the coil, the physician removed the coil from the patient¿s body.The physician switched to a 1.5mm x 2cm coil.Unfortunately, the same issue happened with this coil as it continued to herniate down into the parent vessel.Prior to detaching the coil, the physician removed the coil from the patient¿s body.The physician switched to a 1mm x 1cm coil.This 1mm x 1cm coil successfully deployed into the aneurysm dome and was detached.Upon inspecting the coil mass, as the physician noticed that there was still open space in the middle of the aneurysm, the physician decided to deploy of a second 1mm x 1cm coil into the aneurysm dome.Unfortunately, this second 1mm x 1cm coil mechanically pushed the first detached coil downward and into the parent vessel through and past the stent, ultimately setting the first coil loose into the ica bloodstream.The first coil traveled downstream until it became stuck in the patient¿s distal middle cerebral artery (mca) branches.The physician removed the second 1mm x 1cm coil from the patient without detaching it.The physician then advanced a stent retriever through a microcatheter (subject device), successfully grabbed the loose coil, and started to pull the retriever proximally in hope of removing the stent retriever with the loose coil from the patient¿s body.Unfortunately, the retriever became stuck on the deployed stent as the physician attempted to pass by the struts of the stent.Attempt to re-sheath the retriever stent was not successful.The physician decided to pull the entire system (retriever, stent, and loose coil) as a single unit out of the patient¿s body.Post-procedure angiographic imaging did not reveal any vessel injury or issue to the patient and the final angiographic result looked similar to when the patient arrived ¿ with no coils or stents remaining implanted in the patient.Post-procedure, the patient appeared to be stable.Later the same day night (around 11:00 pm), the patient¿s blood pressure spiked to 186 mmhg.The physician didn't think the blood pressure was treated effectively, and the patient ended up having a massive sub-arachnoid hemorrhage.No additional information is available at this time.
 
Event Description
It was reported that the physician was performing a stent assisted-coiling procedure of a small, un-ruptured, right internal carotid artery (ica) ophthalmic aneurysm in a relatively dysplastic vessel.The stent was successfully deployed across the aneurysm neck using jailed technique.The physician attempted to deploy a first coil, but the coil appeared to be too big and long for the aneurysm, as the coil kept herniating downward into the parent vessel.Prior to detaching the coil, the physician removed the coil from the patient¿s body.The physician switched to a 1.5mm x 2cm coil.Unfortunately, the same issue happened with this coil as it continued to herniate down into the parent vessel.Prior to detaching the coil, the physician removed the coil from the patient¿s body.The physician switched to a 1mm x 1cm coil.This 1mm x 1cm coil successfully deployed into the aneurysm dome and was detached.Upon inspecting the coil mass, as the physician noticed that there was still open space in the middle of the aneurysm, the physician decided to deploy of a second 1mm x 1cm coil into the aneurysm dome.Unfortunately, this second 1mm x 1cm coil mechanically pushed the first detached coil downward and into the parent vessel through and past the stent, ultimately setting the first coil loose into the ica bloodstream.The first coil traveled downstream until it became stuck in the patient¿s distal middle cerebral artery (mca) branches.The physician removed the second 1mm x 1cm coil from the patient without detaching it.The physician then advanced a stent retriever through a microcatheter (subject device), successfully grabbed the loose coil, and started to pull the retriever proximally in hope of removing the stent retriever with the loose coil from the patient¿s body.Unfortunately, the retriever became stuck on the deployed stent as the physician attempted to pass by the struts of the stent.Attempt to re-sheath the retriever stent was not successful.The physician decided to pull the entire system (retriever, stent, and loose coil) as a single unit out of the patient¿s body.Post-procedure angiographic imaging did not reveal any vessel injury or issue to the patient and the final angiographic result looked similar to when the patient arrived ¿ with no coils or stents remaining implanted in the patient.Post-procedure, the patient appeared to be stable.Later the same day night (around 11:00 pm), the patient¿s blood pressure spiked to 186 mmhg.The physician didn¿t think the blood pressure was treated effectively, and the patient ended up having a massive sub-arachnoid hemorrhage.No additional information is available at this time.
 
Manufacturer Narrative
The device history record confirms that the device met all material, assembly and performance specifications.The subject device was not returned for analysis; therefore, physical as well as a functional testing could not be performed.The reported issue is covered in the device directions for use.The risk of the reported event is documented in the risk documentation and there are current controls to mitigate the risk of the as reported event.Information available indicated that the device was confirmed to be in good condition prior to use.Additional information provided by the customer indicated that there was no allegation against the microcatheter and the subject device performed as intended.Based on available information, it cannot be definitively determined if the high blood pressure and massive sub-arachnoid hemorrhage were directly caused by the coil migration and subsequent intervention to remove the coil.The reported patient complications ( hypertension) and patient intracranial hemorrhage are known and anticipated complications to these types of procedures and patient condition and are listed as such in the device directions for use.Therefore, a probable cause of anticipated procedural complication will be assigned to these reported issues.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TREVO 14 PRO MICROCATHETER
Type of Device
CATHETER, INTRAVASCULAR, DIAGNOSTIC
Manufacturer (Section D)
STRYKER NEUROVASCULAR-UTAH-SALT LAKE CITY
4870 west 2100 south
salt lake city UT 84120
MDR Report Key9434308
MDR Text Key176620672
Report Number3012931345-2019-00098
Device Sequence Number1
Product Code DQO
UDI-Device Identifier00815742002317
UDI-Public00815742002317
Combination Product (y/n)N
PMA/PMN Number
K131437
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional
Type of Report Initial,Followup
Report Date 02/13/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model Number90231
Device Catalogue Number90231
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 11/12/2019
Initial Date FDA Received12/06/2019
Supplement Dates Manufacturer Received01/22/2020
Supplement Dates FDA Received02/13/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
4 TARGET COILS (STRYKER); NEUROFORM ATLAS STENT (STRYKER); SYNCHRO GUIDEWIRE (STRYKER); TREVO XP PROVUE RETRIEVER (STRYKER)
Patient Outcome(s) Other;
-
-