Model Number MODEL 100
Device Problem Visual Prompts will not Clear (2281)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 12/06/2019
Event Type  malfunction  
Manufacturer Narrative
The zoll autopulse platform was returned to zoll for investigation.However, investigation is still in progress.A supplemental report will be filed when investigation has been completed.
 
Event Description
As reported, during device setup for patient use, the autopulse platform displayed a user advisory (ua) 45 (driveshaft not at "home" position after power-on/restart) error message.The customer was unable to clear the error.No known impact or patient consequence information was provided.
 
Manufacturer Narrative
The customer's reported complaint of the autopulse platform displayed user advisory (ua) 45 (driveshaft not at "home" position after power-on/restart) error message was confirmed during initial functional testing and archive data review.To remedy the issue, the driveshaft was rotated back to the home position.The likely root cause of the issue was due to user error.Per the autopulse user guide instruction, to clear user advisory (ua) 45, the operator needs to pull up the lifeband until the chest bands are fully extended.This action will move the driveshaft to its home position.The user advisory will persist until the driveshaft is returned to its home position.The autopulse platform passed functional test after drive shaft was rotated to the home position.Visual inspection was performed and found damaged top cover and the front enclosure as a result of user mishandling.To remedy the damage, the top cover and the front enclosure need to be replaced.The autopulse platform is a reusable device.This type of physical damage found during visual inspection is characteristic of normal wear and tear for the age of the device.The archive data review indicated multiple error message user advisory (ua) 45 on the reported event date.The platform was further tested with large resuscitation testing fixture, (lrtf) equivalent to 250 pound patient with good known test batteries for 15 minutes and passed all functional testing criteria and met all required specifications.Historical complaints were reviewed for service information related to the reported complaint and there was no similar complaint reported for autopulse platform sn (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AUTOPULSE® RESUSCITATION MODEL 100
Type of Device
CARDIAC CHEST COMPRESSOR
Manufacturer (Section D)
ZOLL CIRCULATION
2000 ringwood ave.
san jose CA 95131
MDR Report Key9527685
MDR Text Key179286538
Report Number3010617000-2019-01155
Device Sequence Number1
Product Code DRM
UDI-Device Identifier00849111000512
UDI-Public00849111000512
Combination Product (y/n)N
PMA/PMN Number
K112998
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 01/29/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberMODEL 100
Device Catalogue Number8700-0730-01
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/19/2019
Initial Date Manufacturer Received 12/06/2019
Initial Date FDA Received12/27/2019
Supplement Dates Manufacturer Received01/08/2020
Supplement Dates FDA Received01/29/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-