Catalog Number 2C4063K
Device Problem Filling Problem (1233)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 12/04/2019
Event Type  malfunction  
Manufacturer Narrative
(b)(6).Should additional relevant information become available, a supplemental report will be submitted.
 
Event Description
It was reported that a large volume folfusor underinfused during infusion.The reporter indicated that the expected therapy time was 24 hours; however, estimated that only a quarter of the solution had infused at the end of the expected therapy time.The device had been filled with 13.5g piperacillin/tazobactam in an unspecified diluent.There was no report of patient injury or medical intervention associated with this event.No additional information is available.
 
Manufacturer Narrative
H4: the device was manufactured from august 09, 2019 - august 12, 2019.H10: the actual device was received for evaluation.A visual inspection was performed using the naked eye which did not identify any abnormalities that could have contributed to the reported condition.A functional flow rate test was performed and found to be within the product specification range.The reported condition was not verified.A batch review was conducted and there were no deviations found related to this reported condition during the manufacture of this lot.Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FOLFUSOR
Type of Device
PUMP, INFUSION, ELASTOMERIC
Manufacturer (Section D)
BAXTER HEALTHCARE CORPORATION
deerfield IL
MDR Report Key9532013
MDR Text Key173095269
Report Number1416980-2019-07241
Device Sequence Number1
Product Code MEB
UDI-Device Identifier00085412080161
UDI-Public(01)00085412080161
Combination Product (y/n)N
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 01/29/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Catalogue Number2C4063K
Device Lot Number19H011
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/30/2019
Initial Date Manufacturer Received 12/04/2019
Initial Date FDA Received12/30/2019
Supplement Dates Manufacturer Received01/06/2020
Supplement Dates FDA Received01/29/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
PIPERACILLIN/TAZOBACTAM; PIPERACILLIN/TAZOBACTAM
-
-