As per complaint form: literature review title: ''endoscopic stenting for palliation of intra-abdominal gastrointestinal malignant obstruction: predictive factors for clinical success'' pais-cunha et al 2018.As per lit review this study aimed to analyse the factors predicting the effectiveness of stent placement in patients with gastrointestinal obstruction.It was a retrospective study that was carried out including 160 patients who underwent palliative stenting for intra-abdominal obstruction, technical and clinical success, stent dysfunction and adverse events were analysed.''we carried out a retrospective study of a consecutive series of patients undergoing either gastroduodenal or colorectal stent placement for the treatment of malignant intra-abdominal gastroduodenal or colonic obstruction in a tertiary-care medical centre (instituto português de oncologia do porto francisco gentil, e.P.E) between december 2012 and july 2017.'' 'in total, 160 patients had a palliative indication for stent placement and were considered for analysis'.Stent dysfunction occurred in 21 (13%) patients, seven (15%) patients who had undergone colorectal stent placement and 14 (13%) patients who had undergone gastroduodenal stent placement (p = 0.731).Migration was associated with short 6 cm stents (9 vs.2% p = 0.044).Of the 14 patients with stent restenosis, 11 patients had to receive a second stent: 9 gastroduodenal.
|
As per complaint form: literature review title: ''endoscopic stenting for palliation of intra-abdominal gastrointestinal malignant obstruction: predictive factors for clinical success'' pais-cunha et al 2018.As per lit review this study aimed to analyse the factors predicting the effectiveness of stent placement in patients with gastrointestinal obstruction.It was a retrospective study that was carried out including 160 patients who underwent palliative stenting for intra-abdominal obstruction, technical and clinical success, stent dysfunction and adverse events were analysed.''we carried out a retrospective study of a consecutive series of patients undergoing either gastroduodenal or colorectal stent placement for the treatment of malignant intra-abdominal gastroduodenal or colonic obstruction in a tertiary-care medical centre (instituto português de oncologia do porto francisco gentil, e.P.E) between (b)(6)2012 and (b)(6) 2017.'' 'in total, 160 patients had a palliative indication for stent placement and were considered for analysis' stent dysfunction occurred in 21 (13%) patients, seven (15%) patients who had undergone colorectal stent placement and 14 (13%) patients who had undergone gastroduodenal stent placement (p = 0.731).Migration was associated with short 6 cm stents (9 vs.2% p = 0.044).Of the 14 patients with stent restenosis, 11 patients had to receive a second stent: 9 gastroduodenal.
|
K163468 - 510 k # - (exact rpn known but all evo d stents approved under this number.) cannot be confirmed that evo d stent was related to this adverse event.This is a conservative assessment.Device evaluation: the evo stents of unknown lot number were not returned to cook ireland for evaluation.With the information provided, document based investigation was conducted.This file was created from the attached journal article to address nine cases stent restenosis requiring second stent placement with gastroduodenal stent.Lab evaluation: n/a.Documents review including ifu review: as the evo devices from unknown lot number, a review of the relevant manufacturing records cannot be conducted.Prior to distribution all evo (evolution duodenal stent ) devices are subject to visual inspection and functional checks to ensure device integrity.These inspections and functional checks are outlined in internal procedures in place at cirl.The instructions for use ifu0053-10 (for evolution duodenal stent system) which informs the user about the potential complications: those associated with gi endoscopy include, but are not limited to: perforation, hemorrhage, aspiration, reflux, fever, infection, allergic reaction to medication, hypopotension, respiratory depression or arrest, cardiac arrythmia or arrest.Additional complications include, but are not limited to: pancreatitis, intestinal perforation, pain, indadequate expansion, stent misplacement and/or migration, tumor ingrowth or overgrowth, stent occlusion, ulcerations, pressure necrosis, erosion of the luminal muscosa, septicemia, foreign body sensation, bowel impaction, death (other than due to normal disease progression).There is no evidence to suggest that the customer did not follow the instructions for use.Image review: n/a.Root cause review: a definitive root cause could not be determined due to limited information provided in this literature.A possible root cause could be attributed to patient condition related, as per instructions for use, tumor ingrowth or overgrowth, stent occlusion, are listed as a complication following the placement of this device.Summary: customer complaint is confirmed based on customer testimony.The patient was requiring second stent placement.Complaints of this nature will continue to be monitored for potential emerging trends.Attachment: [pais-cunha et al 2018.Pdf].
|