Catalog Number UNK HIP
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Ossification (1428); Unspecified Infection (1930); No Code Available (3191)
Event Date 03/11/2018
Event Type  Injury  
Manufacturer Narrative
(b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.(b)(4).
 
Event Description
Literature article entitled, ¿wear kinetics of highly cross-linked and conventional polyethylene are similar at medium-term follow-up after primary total hip arthroplasty¿ by constantin mayer, md, et al, published by the journal of arthroplasty (2018), vol.33, pp.2671-2676, was reviewed.The aim of this present study was to assess the course and the long-term clinical and radiographic outcomes of thas with ceramic heads (28 and 32 mm) and hclpe inserts over a time course of 3.9-13.8 years.Implanted depuy products: duraloc acetabular cup and locking ring, acetabular screws, marathon polyethylene liner, ceramic femoral head, and s-rom stem and sleeve.All 72 thas in this study were done with depuy components.Results: 3 revisions of unknown products due to infection.25 cases of heterotopic ossification identified on progressive radiographic studies.9 cases of osteolysis identified on progressive radiographic studies.Progressive radiographic studies identified an unknown number of marathon liners with polyethylene wear and femoral head penetration.There were no patient consequences or adverse events associated with the polyethylene wear.Captured in this complaint: cup, head, stem, femoral sleeve, locking ring, and screws: surgical intervention, medical device removal, infection, extraskeletal ossification.(3) liner: surgical intervention, medical device removal, infection, extraskeletal ossification, and osteolysis.(3) liner: implant bearing wear, no patient consequences, no adverse events.
 
Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provision of 21 cfr, part 803.The report may be based on the information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Product complaint # (b)(4).Investigation summary : no device was received.Root cause undetermined.Depuy synthes considers the investigation closed at this time.Should additional information be received, the information will be reviewed and the investigation may be re-opened as necessary.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN HIP IMPLANT
Type of Device
HIP IMPLANT
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
MDR Report Key9587328
MDR Text Key175024642
Report Number1818910-2020-01781
Device Sequence Number1
Product Code JDI
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,l
Type of Report Initial,Followup
Report Date 01/02/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue NumberUNK HIP
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 01/02/2020
Initial Date FDA Received01/14/2020
Supplement Dates Manufacturer Received02/18/2020
Supplement Dates FDA Received03/06/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-