ALCON RESEARCH, LLC - IRVINE TECHNOLOGY CENTER LAUREATE WORLD PHACO SYSTEM, ACCESSORY, HANDPIECE; UNIT, PHACOFRAGMENTATION Back to Search Results
Catalog Number 8065750470
Device Problems Incorrect, Inadequate or Imprecise Result or Readings (1535); Failure to Cut (2587)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 01/09/2020
Event Type  malfunction  
Manufacturer Narrative
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.The manufacturer internal reference number is: (b)(4).
 
Event Description
A healthcare professional reported the vitreous cutting was not working during a cataract with intraocular lens implant (iol) procedure.The procedure was completed because the vitreous cutter was not needed for the procedure.It failed when testing it.
 
Manufacturer Narrative
Additional information is provided in g.1., g.2., h.6.And h.10.No further information was able to be obtained from this customer.With no additional, related information provided, the customers reported event was not able to be confirmed.The manufacturing device history record (dhr) was reviewed.Based on qa assessment, the product met specifications at the time of release.The root cause cannot be determined conclusively.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LAUREATE WORLD PHACO SYSTEM, ACCESSORY, HANDPIECE
Type of Device
UNIT, PHACOFRAGMENTATION
Manufacturer (Section D)
ALCON RESEARCH, LLC - IRVINE TECHNOLOGY CENTER
15800 alton parkway
irvine CA 92618
MDR Report Key9662074
MDR Text Key181833754
Report Number2028159-2020-00061
Device Sequence Number1
Product Code HQC
Combination Product (y/n)N
PMA/PMN Number
K021566
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 02/26/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number8065750470
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 01/10/2020
Initial Date FDA Received02/03/2020
Supplement Dates Manufacturer Received02/25/2020
Supplement Dates FDA Received02/26/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
LAUREATE SYSTEM
-
-