Model Number 73022L
Device Problems Inability to Irrigate (1337); No Flow (2991)
Patient Problems No Consequences Or Impact To Patient (2199); No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete, a supplemental report will be filed.The device was not returned.
 
Event Description
It was reported that there was no flow from the 3-way silicone foley catheter, and the physician was unable to irrigate the catheter using a syringe.Reportedly, it was the second time the incident had occurred.
 
Event Description
It was reported that there was no flow from the 3-way silicone foley catheter, and the physician was unable to irrigate the catheter using a syringe.Reportedly, it was the second time the incident had occurred.
 
Manufacturer Narrative
The device was not returned for evaluation.A potential failure mode could be ¿reduced or no irrigation flow¿ with a potential root cause of ¿kinked/pinched irrigation lumen or no irrigation eye¿.The lot number is unknown; therefore, the device history record could not be reviewed.The instructions for use were found adequate and state the following: ¿to deflate catheter balloon: gently insert a luer slip tip syringe in the catheter valve.Never use more force than is required to make the syringe ¿stick¿ in the valve.Allow the pressure within the balloon to force the plunger back and fill the syringe with water.If you notice slow or no deflation, re-seat the syringe gently.Use only gentle aspiration to encourage deflation if needed.Vigorous aspiration may collapse the inflation lumen, preventing balloon deflation.If necessary, contact adequately trained professional for assistance, as directed by hospital protocol.Should balloon rupture occur, care should be taken to assure that all balloon fragments have been removed from the patient." h11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : the device was not returned.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BARDEX® LUBRI-SIL® ALL-SILICONE FOLEY CATHETER
Type of Device
BARD LUBRISIL FOLEY CATHETER
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
MDR Report Key9750772
MDR Text Key184297152
Report Number1018233-2020-01315
Device Sequence Number1
Product Code EZL
UDI-Device Identifier00801741034329
UDI-Public(01)00801741034329
Combination Product (y/n)N
PMA/PMN Number
K070558
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,other
Type of Report Initial,Followup
Report Date 03/19/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number73022L
Device Catalogue Number73022L
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 02/03/2020
Initial Date FDA Received02/25/2020
Supplement Dates Manufacturer Received03/10/2020
Supplement Dates FDA Received03/19/2020
Is This a Reprocessed and Reused Single-Use Device? No