Model Number NOT APPLICABLE
Device Problems Display or Visual Feedback Problem (1184); Fluid/Blood Leak (1250)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 02/13/2020
Event Type  malfunction  
Manufacturer Narrative
The system was used for treatment.This case is reportable as a mdr due to the reportable malfunction tubing leak.Since this reportable malfunction is only associated with the kit, this mdr will only be against the kit.A batch record review for kit lot h146 was conducted.There were no non-conformances associated with this lot.This lot met all release requirements.A review of kit lot h146 shows no trends.Trends were reviewed for complaint categories, tubing leak, alarm #55: collect pump (#1) error, and system error 30.No trends were detected for this complaint category.The assessment is based on the information available at the time of investigation.No product was returned for investigation; therefore, it could not be determined if the product met specification based solely on the information provided by the customer.Complaints are monitored through tracking and trending.If a trend is detected, further investigation will be conducted.Investigation complete.(b)(4).
 
Event Description
The customer contacted mallinckrodt to report that they experienced a tubing leak with their cellex photopheresis kit ("kit") during an extracorporeal photopheresis (ecp) treatment.The customer reported they received an alarm #55: collect pump (#1) error during the prime phase of the procedure.The customer stated they manually turned the collect pump and completed the prime.The treatment proceeded until the customer received a system error 30 alarm, and then observed blood leaking from the collect pump tubing.The customer aborted the ecp treatment and did not return residual blood within the kit to the patient.The patient was reported to be in stable condition and received a saline bolus.The customer did not return product for investigation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CELLEX PHOTOPHERESIS SYSTEM
Type of Device
CELLEX PHOTOPHERESIS SYSTEM
Manufacturer (Section D)
THERAKOS INC.
bedminster, nj
Manufacturer (Section G)
MALLINCKRODT PHARMACEUTICALS IRELAND LIMITED
college business & tech park
cruiserath road
blanchardstown, dublin, D15 T X2V
EI   D15 TX2V
Manufacturer Contact
megan vernak
1425 us route 206
bedminster, nj 
MDR Report Key9828670
MDR Text Key195363799
Report Number2523595-2020-00037
Device Sequence Number1
Product Code LNR
Combination Product (y/n)N
Reporter Country CodeIT
PMA/PMN Number
P860003
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional
Reporter Occupation Nurse
Type of Report Initial
Report Date 03/13/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date08/01/2021
Device Model NumberNOT APPLICABLE
Device Catalogue NumberCLXECP
Device Lot NumberH146
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 02/13/2020
Initial Date FDA Received03/13/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured08/27/2019
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-