Model Number 1365-36-330
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Foreign Body Reaction (1868); Pain (1994); Swelling (2091); Joint Disorder (2373); Osteolysis (2377); Limited Mobility Of The Implanted Joint (2671); No Code Available (3191)
Event Date 09/10/2019
Event Type  Injury  
Manufacturer Narrative
(b)(4).Initial reporter occupation: lawyer.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
Now that the operation report is available and after consultation with the attending doctor at the speising orthopedic hospital, it has become apparent that there has been an obvious loosening of the implant and a massive pain situation due to metal abrasion, with massive metal-synovitic tissue having to be removed intraoperatively.Doi: (b)(6) 2009; dor: (b)(6) 2019; (right hip).
 
Event Description
After review of the surgery report, patient was revised to address loosening of the cup with metallosis.Revision notes stated that there were massively swollen joint capsule found from which a dark fluid drained and luxation of the hip joint striking off the head was noted.
 
Manufacturer Narrative
Product complaint # (b)(4).Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Patient code: no code available (3191) used to capture the device revision or replacement.
 
Manufacturer Narrative
Product complaint (b)(4).Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H10 additional narrative: added: h6 (patient code).No code available (3191) used to capture the joint instability.Product complaint (b)(4).Investigation summary: no device associated with this report was received for examination.A worldwide complaint database search made over the last three year period did identify two previous complaints (b)(4).Against the provided product/lot combination(s).However, a review of these complaints confirmed that these had both been metal on metal implant combinations.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Corrective action was not indicated.If information is obtained that was not available for the initial medwatch, a follow-up medwatch, a follow-up medwatch will be filed as appropriate.
 
Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Product complaint # (b)(4).Investigation summary: no device associated with this report was received for examination.A worldwide complaint database search found no additional related incident(s) against the provided product/lot combination(s) since release for distribution.Based on previous investigations this complication of joint replacement is unlikely to have been the result of a device failing to meet required specifications.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Corrective action was not indicated.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Product complaint # (b)(4).Investigation summary: no device associated with this report was received for examination.A worldwide complaint database search found no additional related incident(s) against the provided product/lot combination(s) since release for distribution.Based on previous investigations this complication of joint replacement is unlikely to have been the result of a device failing to meet required specifications.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Corrective action was not indicated.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DELTA CER HEAD 12/14 36MM +8.5
Type of Device
ARTICULEZE HEAD (12/14 TAPER) : HIP CERAMIC FEMORAL HEADS
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
MDR Report Key9921906
MDR Text Key186346508
Report Number1818910-2020-10133
Device Sequence Number1
Product Code MRA
UDI-Device Identifier10603295033639
UDI-Public10603295033639
Combination Product (y/n)N
PMA/PMN Number
K031803
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer,foreign,other
Type of Report Initial,Followup,Followup,Followup,Followup
Report Date 03/18/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date10/31/2013
Device Model Number1365-36-330
Device Catalogue Number136536330
Device Lot Number2761807
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 03/18/2020
Initial Date FDA Received04/03/2020
Supplement Dates Manufacturer Received04/24/2020
04/15/2020
05/12/2020
06/01/2020
Supplement Dates FDA Received04/30/2020
05/08/2020
05/14/2020
06/03/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
APEX HOLE ELIM POSITIVE STOP; CORAIL2 STD SIZE 13; PINNACLE 100 HA ACET CUP 52MM; PINNACLE MTL INS NEUT36IDX52OD
Patient Outcome(s) Required Intervention;
Patient Age77 YR
-
-