COVIDIEN EVERFLEX SELF-EXPANDING PERIPHERAL STENT WITH ENTRUST DELIVERY SYSTEM LONG; STENT, SUPERFICIAL FEMORAL ARTERY Back to Search Results
Model Number EVD35-07-150-150
Medical Device Problem Code Positioning Problem (3009)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 03/31/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The entrust stent delivery system, (sds), was received within a sealed tyvek pouch, within a sealed plastic biohazard pouch, and loosely coiled within a zipper closure plastic biohazard pouch, along with a 0.014¿ guidewire.The entrust sds was received with the red safety tab removed from the handle, locked up on the 0.014¿ guidewire, the inner guidewire lumen folded up within the safety tab cavity of the handle, and approximately 2mm of the stent exposed.If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
Physician intended to use a pacific xtreme pta balloon with a 6fr non-medtronic sheath and non-medtronic guidewire during treatment of a 200mm calcified lesion in the patient¿s mid left superficial femoral artery (sfa) of diameter 6mm.Slight vessel tortuosity and severe calcification is reported.No damage noted to product packaging prior to use.No issues noted when removing the device from the packaging.Ifu was followed and the device was prepped without issue.The device was not passed through a previously deployed stent.No resistance is reported during advancement of the device.50/50 saline/contrast mix was used for balloon inflation.It is reported that a balloon burst occurred during inflation of the balloon.Balloon did not fragment.No vessel damage was noted.The balloon was safely removed from the patient without intervention.The physician then decided to treat with an everflex entrust self-expanding stent system using the same sheath and wire.No damage noted to product packaging prior to use.No issues noted when removing the device from the packaging.Ifu was followed and the device was prepped without issue.No resistance was encountered during advancement.It is reported the everflex entrust stent was unable to cross the lesion.The device was safely removed from the patient.The physician then used a non-medtronic stent to complete the procedure.No patient injury reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EVERFLEX SELF-EXPANDING PERIPHERAL STENT WITH ENTRUST DELIVERY SYSTEM LONG
Common Device Name
STENT, SUPERFICIAL FEMORAL ARTERY
Manufacturer (Section D)
COVIDIEN
4600 nathan lane north
plymouth MN 55442
MDR Report Key10074627
Report Number2183870-2020-00148
Device Sequence Number19545236
Product Code NIP
UDI-Device Identifier00821684051719
UDI-Public00821684051719
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
P110023
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 05/20/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/21/2022
Device Model NumberEVD35-07-150-150
Device Catalogue NumberEVD35-07-150-150
Device Lot NumberA803040
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/13/2020
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/14/2020
Initial Report FDA Received Date05/20/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-