BIOMET MICROFIXATION TMJ SYSTEM LEFT NARROW MANDIBULAR COMPONENT 45 MM / 6 HOLE; JOINT, TEMPOROMANDIBULAR, IMPLANT
|
Back to Search Results |
|
| Model Number |
N/A |
| Medical Device Problem Code |
Migration or Expulsion of Device (1395)
|
| Health Effect - Clinical Codes |
Swelling (2091); Sleep Dysfunction (2517)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Zimmer biomet complaint (b)(4).The device will not be returned for analysis as it remains implanted; however, an investigation of the reported event is in progress.Once the investigation is completed, a supplemental medwatch 3500a will be submitted.Multiple mdr reports were filed for this event, please see associated reports: 0001032347-2020-00237, 0001032347-2020-00238, 0001032347-2020-00239, 0001032347-2020-00240.Concomitant medical products: tmj system left narrow mandibular component 45 mm / 6 hole, part# 01-6546, lot# 862970c.Tmj system left fossa component, small, part# 24-6563, lot# 886860c.2.4mm system high torque (ht) cross-drive screw 2.7mm x 8mm, part# 91-2708, lot# ni.2.4mm system high torque (ht) cross-drive screw 2.7 x 10mm, part# 91-2710, lot# ni.Tmj system cross drive fossa screw 2.0mm x 7mm, part# 99-6577, lot# ni.Initial reporter patient.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient attended oral therapy sessions and a potentially loose screw was discovered following implantation of temporomandibular implants on the left side eleven (11) months ago.The patient reports swelling on the left side of the mouth and face, and reports difficulty sleeping on the left side.The patient attended ten oral therapy sessions to reportedly break down scar tissue, and the therapist discovered a possibly loose screw.No additional patient consequences have been reported.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional information.The complaint is considered to be confirmed because the patient received additional treatment from the oral therapist.No product was returned; therefore, no functional tests or inspections could be performed.No x-rays, scans, pictures, or physician's reports were provided.The dhr for the mandible was reviewed; no non-conformances were found.There are no indications of manufacturing defects.This is the only complaint for this item# 01-6546, lot# 862970c.For all non-custom tmj mandibular implants in the previous one year (from the notification date) regarding swelling, there is a (b)(4), which is no greater than the occurrence listed in the application fmea.For all non-custom tmj mandibular implants in the previous one year (from the notification date) regarding scar tissue, there is a (b)(4), which is no greater than the occurrence listed in the application fmea.For all non-custom tmj mandibular implants in the previous one year (from the notification date) regarding a loose screw, there is a (b)(4), which is no greater than the occurrence listed in the application fmea.The most likely underlying cause of the complaint could not be determined.
|
| |
|
Event or Problem Description
|
|
This follow-up report is being submitted to relay additional information.
|
| |
|