ETHICON ENDO-SURGERY, LLC. PWRD ECH FLEX 60MM 44CM SHAFT; STAPLE, IMPLANTABLE Back to Search Results
Model Number PLE60A
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 04/29/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).Attempts have been made to retrieve the device.To date, the device has not been returned.If the device or further details are received at a later date, a supplemental medwatch will be sent.A manufacturing record evaluation was performed for the finished device lot number, and no non-conformance were identified.
 
Event or Problem Description
It was reported that during a laparoscopic sleeve gastrectomy, after severing gastric tissue on the third firing, it was noted that staples were malformed with irregular shapes.Changed to a new one to complete surgery.There was no patient consequence reported.No additional information can be provided.
 
Additional Manufacturer Narrative
(b)(4).Date sent: 6/29/2020.D4: batch #t5dv9w.Investigation summary the analysis found that one ple60a device was returned with no apparent damage and with an ecr60b fully fired cartridge loaded on the device.In addition, four reloads were received.The reloads were received fully fired.The device was tested for functionality in the straight position with a test cartridge reload and achieved its complete firing sequence without any difficulties.The staple line and cut line were complete and the staples met the staple form release criteria.However, the cut was noted to be jagged due to a damaged knife.A manufacturing record evaluation was performed for the finished device batch number, and no non-conformance were identified.One possible cause for this type of damage to the knife is when the device is fired over an already existing staple line, hard object or thicker tissue than indicated.Repeatedly firing across existing staple lines can also reduce the ability to cut cleanly.To mitigate the potential for staples getting into the cartridge and interfering with the knife path during device firing, prior to reloading the device, rinse the anvil and cartridge jaw in sterile solution and then wipe the anvil and cartridge jaw to clean any formed but unused staples from the device.Additionally, proper care should be taken when placing the device on the tissue to be stapled to ensure that no hard obstruction, such as a clip, is included with the tissue inside the jaws.As part of our quality process, each device is visually inspected and functionally tested during manufacturing to ensure that the device met the required specifications prior to shipment.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PWRD ECH FLEX 60MM 44CM SHAFT
Common Device Name
STAPLE, IMPLANTABLE
Manufacturer (Section D)
ETHICON ENDO-SURGERY, LLC.
475 calle c
guaynabo 00969
MDR Report Key10098712
Report Number3005075853-2020-02742
Device Sequence Number16380738
Product Code GDW
UDI-Device Identifier10705036014300
UDI-Public10705036014300
Combination Product (Y/N)N
PMA/510(K) Number
K110385
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 04/30/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/31/2022
Device Model NumberPLE60A
Device Catalogue NumberPLE60A
Device Lot NumberT94G1H
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/01/2020
Initial Date Received by Manufacturer 04/30/2020
Supplement Date Received by Manufacturer06/01/2020
Initial Report FDA Received Date05/28/2020
Supplement Report FDA Received Date06/29/2020
Patient Sequence Number1
-
-