COVIDIEN 450 SAL EJECTOR 3283; MOUTHPIECE, SALIVA EJECTOR Back to Search Results
Model Number 8881450004
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 05/21/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The incident sample has been requested but to date has not been received for evaluation. if the sample is received, or if additional information pertinent to the incident is obtained a follow-up report will be submitted. as part of our manufacturing process, all device history records are reviewed and approved by quality, prior to release of product.
 
Event or Problem Description
The customer reported that during inspection before use, they pulled the tip and the cover was removed easily.There was no patient harm was reported.
 
Additional Manufacturer Narrative
The device history record was reviewed, and no abnormal process conditions were present during the manufacturing of the product that could have led to the defect described by the customer.The device history record review showed that all acceptance criteria inspections per established sampling levels were within acceptable limits during the production process.Nine decontaminated samples were received at the manufacturing site for evaluation without the original packaging or lot number.Upon a visual evaluation of the sample, it was identified that only a loose blue cap was found in the received samples.The issue was confirmed.During a previous investigation for a similar issue with a similar condition, a gemba walk was completed with the multifunctional team at the manufacturing site and it has been determined that the potential root cause for the reported issue could be worn out grippers and springs.At the end of the assembly process a pull test is performed on the tubing and the tip assembly, if there is a worn-out gripper and springs it is possible for the machine to grab the tube incorrectly.As part of continuous improvements, the following actions were performed to address the reported issue: 1.Included additional red rabbits, pull test.2.Work order registered to document the changed grippers and springs.3.Work order for station calibration from 2 to 5 pounds for pull test.4.A maintenance job plan was created.This complaint will be used for qa tracking and trending purposes.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
450 SAL EJECTOR 3283
Common Device Name
MOUTHPIECE, SALIVA EJECTOR
Manufacturer (Section D)
COVIDIEN
calle 9 sur no. 125 cuidad ind
tijuana 22500
MX  22500
MDR Report Key10105246
Report Number9612030-2020-02482
Device Sequence Number16821129
Product Code DYN
UDI-Device Identifier10884521020337
UDI-Public10884521020337
Combination Product (Y/N)N
Initial Reporter CountryJA
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 08/13/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device No Information
Device Model Number8881450004
Device Catalogue Number8881450004
Device Lot Number1933306964
Was Device Available for Evaluation? Yes
Initial Date Received by Manufacturer 05/25/2020
Supplement Date Received by Manufacturer05/25/2020
Initial Report FDA Received Date06/01/2020
Supplement Report FDA Received Date08/13/2020
Patient Sequence Number1
-
-