• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: WRIGHTS LANE SYNTHES USA PRODUCTS LLC SYNFIX EVOLUTION AWL/WITHOUT SLEEVE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

WRIGHTS LANE SYNTHES USA PRODUCTS LLC SYNFIX EVOLUTION AWL/WITHOUT SLEEVE Back to Search Results
Model Number 03.835.032
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Patient Involvement (2645)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Reporter is a j&j employee.The device has been received, the investigation is in progress, no conclusion could be drawn at the time of filing this report.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported that on an unknown date, during a routine incoming inspection of the loaner set, it was observed that the synfix evolution awl without sleeve was broken.There was no patient involvement.This report is for 1 synfix® evolution awl/without sleeve.This is report 1 of 1 for complaint (b)(4).
 
Additional Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Visual inspection: the synfix® evolution awl/without sleeve (part # 03.835.032 / lot # l319015) was received at us cq.There was no evidence of device breakage, the device appeared to be in good shape.Upon further inspection the distal end of the device was noticed to be deformed.Based on the device design, the tip should be sharp but the tip was bent and flat at the end.The overall complaint of broken was not confirmed as there was no evidence of device breakage.Device failure/defect identified? yes; tip was deformed.Dimensional inspection: no dimensional inspection was performed as there was no access to relevant components.Document/specification review: drawing(s) reviewed: (current & manufactured revisions).Conclusion: the overall complaint was not confirmed for the received synfix® evolution awl/without sleeve (part # 03.835.032 / lot # l319015) as there was no device breakage.Although no definitive root-cause can be determined, it is possible the tip of the device has worn out due to repetitive use, contributing to the deformed condition.There was no indication that a design or manufacturing issue contributed to the complaint.No design issues were observed during the document/specification review.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post market safety surveillance activities.Device history: part number: 03.835.032, lot number: l319015, manufacturing site: hägendorf, release to warehouse date: 22.May 2017.A manufacturing record evaluation was performed for the finished device lot number, and no non-conformances were identified.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNFIX EVOLUTION AWL/WITHOUT SLEEVE
Common Device Name
AWL
Manufacturer (Section D)
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
1302 wrights lane east
west chester PA 19380
MDR Report Key10125397
Report Number2939274-2020-02687
Device Sequence Number2924672
Product Code HWJ
UDI-Device Identifier10705034814179
UDI-Public(01)10705034814179
Combination Product (Y/N)N
Initial Reporter StateMA
Initial Reporter CountryUS
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 05/27/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number03.835.032
Device Catalogue Number03.835.032
Device Lot NumberL319015
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/04/2020
Initial Date Received by Manufacturer 05/27/2020
Supplement Date Received by Manufacturer06/26/2020
Initial Report FDA Received Date06/05/2020
Supplement Report FDA Received Date07/09/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-