| Model Number |
320-46-03 |
| Medical Device Problem Codes |
Detachment of Device or Device Component (2907); Device Dislodged or Dislocated (2923)
|
| Health Effect - Clinical Codes |
Failure of Implant (1924); Pain (1994)
|
| Date of Event |
05/20/2020
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Pending evaluation: concomitant medical device(s): 320-01-46, 5787150 - equinoxe reverse 46mm glenosphere; 320-15-05, 5722834 - eq rev locking screw; 320-10-00, 5775079 - equinoxe reverse tray adapter plate tray +0; 320-20-00, 5666835 - eq reverse torque defining screw kit; 300-01-13, 5683442 - equinoxe, humeral stem primary, press fit 13mm.
|
| |
|
Event or Problem Description
|
|
Approximately 10 weeks postop the initial left tsa, an (b)(6) y/o male patient¿s poly became disengaged in the left shoulder causing a revision.The surgeon wanted to revise the glenosphere as well.As a result, he ¿rebroke¿ the screw on the tray, and when he went to dislodge the tray from the stem, the entire stem came loose causing a necessary full revision of the humeral side as well.Patient was last known to be in stable condition following the event.Patient was last known to be in stable condition following the event.Device is available for return.Humeral loosening is captured under 1038671-2020-00294.
|
| |
|
Additional Manufacturer Narrative
|
|
Section h10: (h3) the revision reported was likely the result of may have been the result of incomplete seating of the humeral liner during implantation, forceful contact between the liner and glenoid bone (scapular notching), extreme wear of the liner, or a combination of the three, which led to the humeral liner disassociating from the humeral tray.
|
| |
|
Event or Problem Description
|
|
Approximately 1 year, 1 month, 28 days postop of the initial left tsa, the patient¿s poly became disengaged in the left shoulder causing a revision.The surgeon wanted to revise the glenosphere as well.As a result, he ¿rebroke¿ the screw on the tray, and when he went to dislodge the tray from the stem, the entire stem came loose causing a necessary full revision of the humeral side as well.Patient was last known to be in stable condition following the event and the clinical report indicates that this event is definitely related to the device(s) and/or to the procedure.
|
| |
|
Additional Manufacturer Narrative
|
|
After further review of additional information received the following sections b5, g1, g3, g6, h1, h2, h3 and h6 have been updated accordingly.Concomitant devices: 320-01-46, (b)(6) - equinoxe reverse 46mm glenosphere.320-15-05, (b)(6)- eq rev locking screw.320-20-00, (b)(6) - eq reverse torque defining screw kit.300-01-13, (b)(6) - equinoxe, humeral stem primary, press fit 13mm.
|
| |
|
Additional Manufacturer Narrative
|
|
1038671-2024-03558 this follow-up report is being submitted to relay additional and/or corrected information.Multiple mdr reports were filed for this event, please see associated reports: 1038671-2024-03558.The following sections were updated: g1, h6.The following sections were corrected: b1, b2, g1, h6.The revision reported was likely the result of may have been the result of incomplete seating of the humeral liner during implantation, forceful contact between the liner and glenoid bone (scapular notching), extreme wear of the liner, or a combination of the three, which led to the humeral liner disassociating from the humeral tray.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|