TERUMO BCT TRIMA ACCEL; TRIMA ACCEL LRS PLATELET + AUTO PAS, PLASMA, RBC SET Back to Search Results
Model Number 80410
Medical Device Problem Code No Apparent Adverse Event (3189)
Health Effect - Clinical Codes Hypersensitivity/Allergic reaction (1907); Skin Discoloration (2074); No Known Impact Or Consequence To Patient (2692)
Date of Event 05/21/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Investigation: a photograph was submitted to aid in the investigation.Analysis of the image revealed a used trima access needle assembly containing blood inserted into a patient¿s arm.Tape on the patient¿s arm is seen holding the access needle in place.A rectangular red spot is seen on the patient's arm with adhesive residue in spots.It is unknown if a large sterile dressing was applied to the site at any point during the procedure.Based on the evidence found in the image provided, a definitive root cause of this failure could not be determined at this time.Investigation is in process.A follow-up report will be provided.
 
Event or Problem Description
The customer reported a donor having an allergic reddish arm a the needle site while donating on a trima device.It is unknown at this time if medical intervention was required for this event.Patient information and outcome are not available at this time.The platelet collection set is not available for return because it was discarded by the customer.
 
Additional Manufacturer Narrative
This report is being filed to provide additional information in e1, e3, h6 and h10.The customer declined to provide reporter first name and address of the customer site.Investigation: a review of the device history record (dhr) for this unit showed no irregularities during manufacturing that were relevant to this issue.Root cause: based on review of the image provided, a definitive root cause for the donor's reaction could not be determined.Possible causes include but are not limited to an allergy to the disposable tubing, tape for venipuncture or sterile dressing, and/or donor sensitivity to eto.
 
Additional Manufacturer Narrative
This report is being filed to provide additional information in b.6, h.6 and h.10 and corrected infromation in h.1.Investigation: further evaluation of this event has determined that the device did not cause or contribute to a death or serious injury, nor is there a likely potential for death or serious injury associated with this event based on additional investigational information.It was confirmed by the customer that no medical intervention was required for the allergic reaction.Investigation is in process.A follow up report will be provided.
 
Event or Problem Description
It was confirmed by the customer during follow-up that no medical intervention was required for the allergic reaction and the customer finished the collection process.
 
Additional Manufacturer Narrative
This report is being filed to provide additional information in b.5 and h.10.Investigation: based on literature reference, therapeutic apheresis: a physician's handbook, allergic reactions are usually associated with replacement procedures that include blood components, but sensitivity to disposable tubing sterilized with ethylene oxide can also be associated with allergic reactions.Investigation is in process.A follow up report will be provided.
 
Event or Problem Description
The customer declined to provide patient information.The patient is reported as stable.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRIMA ACCEL
Common Device Name
TRIMA ACCEL LRS PLATELET + AUTO PAS, PLASMA, RBC SET
Manufacturer (Section D)
TERUMO BCT
lakewood CO 80215
MDR Report Key10153510
Report Number1722028-2020-00292
Device Sequence Number3637140
Product Code GKT
UDI-Device Identifier05020583804104
UDI-Public05020583804104
Combination Product (Y/N)N
Initial Reporter CountryTH
PMA/510(K) Number
BK190332
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source foreign,health professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup,Followup
Report Date (Section B) 06/15/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date08/01/2021
Device Model Number80410
Device Catalogue Number80410
Device Lot Number1908152130
Was Device Available for Evaluation? No
Was the Report Sent to FDA? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/21/2020
Supplement Date Received by Manufacturer06/22/2020
09/18/2020
10/19/2020
Initial Report FDA Received Date06/15/2020
Supplement Report FDA Received Date07/07/2020
10/05/2020
10/28/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-