SMITH & NEPHEW ORTHOPAEDICS AG POLARSTEM COLLAR REAMER GUIDE; PROSTH, HIP, SEMI-CONST, MET/CERAM/POLY, CEMENT OR NON-POROUS, UNCEMENT
|
Back to Search Results |
|
| Model Number |
75102205 |
| Medical Device Problem Code |
Connection Problem (2900)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
04/16/2020
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that when cleaning and putting the polarstem collar reamer guide set together, the spring came out of the reamer guide.No procedure-related.
|
| |
|
Additional Manufacturer Narrative
|
|
A polarstem collar reamer guide (75102205), used in treatment, was not received for evaluation.It was reported that when cleaning and putting the polarstem collar reamer guide set together, the spring came out of the reamer guide.This did not happen during a procedure, there is no information available on how the reamer guide broke.A visual analysis could not be conducted, as the part was not returned.The production documentation was not reviewed, as not batch number was received.The review of the complaint database showed that similar cases were reported in the past, one of which led to a corrective and preventive action.A design review was performed which demonstrated that the hook may contact the reamer if it is not fully engaged to the rasp during reaming.This collision might lead to a fracture of the hook and the spring can become loose.However a breakage was not reported in this case.A new design of the device has been released in order to prevent the reoccurrence of this issue.The failure mode cannot be independently confirmed as the part was not returned.The root cause is attributed to insufficient design specifications.Further investigations have been initiated to review the performance of this device.This complaint has been reopened for reporting reasons, according to the current procedure.No additional information became available.Should the device be returned, this complaint will be reassessed.Smith and nephew will monitor this version of the device for further similar issues.
|
| |
|
Additional Manufacturer Narrative
|
|
A polarstem collar reamer guide (75102205), used in treatment, was received for evaluation.It was reported that when cleaning and putting the polarstem collar reamer guide set together, the spring came out of the reamer guide.This did not happen during a procedure, there is no information available on how the reamer guide broke.A visual analysis could confirm that the hook of the reamer guide is broken apart.All pieces including the spring were returned for evaluation.The reamer guide shows some minor signs of use.The production documentation was reviewed, there were no deviations found.The review of the complaint database showed that similar cases were reported in the past, one of which led to a corrective and preventive action.A design review was performed which demonstrated that the hook may contact the reamer if it is not fully engaged to the rasp during reaming.This collision might lead to a fracture of the hook and the spring can become loose.However a breakage was not reported in this case.A new design of the device has been released in order to prevent the reoccurrence of this issue.The failure mode can be confirmed.The root cause is attributed to insufficient design specifications.Further investigations have been initiated to review the performance of this device.A field action was started to remove some batches of this instrument, including the one in scope, from the market.This complaint has been reopened as the part was received for investigation.Smith and nephew will monitor this version of the device for further similar issues.The returned device will be archived.
|
| |
|