• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ZIMMER MANUFACTURING B.V. BONE SCREW SELF-TAPPING 4.5 MM DIA. 40 MM LENGTH; PROSTHESIS, HIP

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ZIMMER MANUFACTURING B.V. BONE SCREW SELF-TAPPING 4.5 MM DIA. 40 MM LENGTH; PROSTHESIS, HIP Back to Search Results
Model Number N/A
Medical Device Problem Code Fracture (1260)
Health Effect - Clinical Code Foreign Body In Patient (2687)
Date of Event 05/27/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).Foreign report source: (b)(6).Customer has indicated that the product will not be returned to zimmer biomet for investigation as the device remains implanted in the patient.The investigation is in process.Once the investigation has been completed, a follow-up mdr will be submitted.
 
Event or Problem Description
It was reported that during an initial hip arthroplasty, the screw broke during the placement of the osteosynthesis plate, a piece remained in the patient's bone.The screw was left in the patient's bone because the removal trial could have damaged the plate.Attempts have been made and additional information on the reported event is unavailable at this time.
 
Additional Manufacturer Narrative
This follow-up report is being submitted to relay additional information.  the following sections were.Updated: b4, b5, g4, g7, h1, h2, h3, h6, h10.Reported event was unable to be confirmed due to limited information received from the customer.Review of the device history records identified no deviations or anomalies during manufacturing.Root cause was unable to be determined as the necessary information to adequately investigate the reported event was not provided.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Event or Problem Description
No further event information available at the time of this report.
 
Additional Manufacturer Narrative
This follow-up report is being submitted to relay additional information.  a trilogy bone screw was returned.Visual evaluation identified the following: the screw was fractured.The fracture piece was retained in the patient's body.The hex head exhibited nicks and scratches indicative of implantation attempts.No other damages were noted.Further analysis identified the following: the bone screw's fracture surface showed suspected crack initiation and exit areas.Sheared ductile overload dimples were present throughout the fracture surface.Material analysis of the bone screw confirmed that the material was consistent with ti-6al-4v alloy.No further evaluation could be performed with the returned product.Complaint sample was evaluated and the reported event was confirmed.Evaluation of the returned product does not change the final conclusions of previous investigation.The root cause could not be determined with the information provided.A summary of the investigation has been sent to the complainant.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Event or Problem Description
No further event information available at the time of this report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BONE SCREW SELF-TAPPING 4.5 MM DIA. 40 MM LENGTH
Common Device Name
PROSTHESIS, HIP
Manufacturer (Section D)
ZIMMER MANUFACTURING B.V.
turpeaux industrial park
route #1 km 123.4 bldg #1
mercedita PR 00715
MDR Report Key10200179
Report Number0002648920-2020-00315
Device Sequence Number2613050
Product Code MRA
UDI-Device Identifier00889024119765
UDI-Public(01)00889024119765(17)290831(10)64485654
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
K934765
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 03/12/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberN/A
Device Catalogue Number00625004540
Device Lot Number64485654
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/28/2021
Was the Report Sent to FDA? No
Initial Date Received by Manufacturer 06/15/2020
Supplement Date Received by Manufacturer10/08/2020
03/10/2021
Initial Report FDA Received Date06/26/2020
Supplement Report FDA Received Date10/13/2020
03/12/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
If action reported to FDA under 21 USC 360i(g), list
FDA-assigned Recall Number or include a statement
N/A
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-