| Model Number |
N/A |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Hypersensitivity/Allergic reaction (1907); Inflammation (1932); Pain (1994); Swelling (2091); Reaction (2414); Swelling/ Edema (4577)
|
| Date of Event |
10/29/2019
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
(b)(4).Concomitant medical products: associated products : item#:42538000701; partial tibial cemented size g left medial lot#:63775672.Item#:unknown; bcm-palacos-standard-unk lot#:unknown.Item#:unknown; bcm-gentamycin-unknown-- lot#:unknown.Item#:42518200708; partial articular surface left medial size g 8 mm thickness; lot#:63707718.Reported event was confirmed by review of medical records.No product was returned or pictures provided; visual and dimensional evaluations could not be performed.Device history record (dhr) was reviewed and no discrepancies related to the reported event were found.Revision operative notes were provided and it confirms that patient underwent revision due to nickel allergy.During revision the implants were seen to be well fixed and intact.Synovitis was debrided and there were no signs of infection.Office follow up notes prior to surgery stated that patient had pain and swelling.X-rays were provided however they were not sent for review as evaluation would not be able to confirm the presence of a nickel allergy therefore sending images to mmi would not enhance the investigation.It was reported that patient was revised due to allergic reaction, hence the root cause can be attributed towards patient condition.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Event or Problem Description
|
|
It is reported the patient had an initial left partial tkr, and subsequently was revised approximately 20 months later due to pain, swelling, and metal allergy.
|
| |
|
Event or Problem Description
|
|
No further event information available at the time of this report.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional information.The following sections were updated: b4; b5; g3; g6; h1; h2; h3; h6; h11 h6: component code: mechanical (g04) - femur the reported event was confirmed.No devices were received; therefore the condition of the components is unknown.The device history record was reviewed and no discrepancies relevant to the reported event were found.Medical records provided state that patient was revised due to metal allergy (nickel allergy), pain and inflammation.Additional medical records provided state that patient was experiencing pain with swelling.Per instructions for use per component description, the femoral component contain the elements that patient is allergic to.The ifu also states under adverse effects material sensitivity and is a known inherent risk.The root cause is attributed to use error via a failure to follow instructions.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|