Device was used for treatment, not diagnosis.If information is obtained that was not available for this medwatch, a supplemental medwatch report will be filed as appropriate.The reporter¿s phone number was not provided.Concomitant med products and therapy dates: lid device, (b)(6) 2020.The actual device has been returned and is currently pending evaluation.Once the investigation has been completed, and if additional information should become available, a supplemental medwatch report will be submitted accordingly.Udi: (b)(4).
|
|
It was reported from (b)(6) that the lid device detached from the casing device.It was not reported if the device was used in surgery, or if there was patient involvement.It was not reported if there were any delays in a surgical procedure or if a spare device was available.There were no reports of injuries, medical intervention or prolonged hospitalization.The exact date of the event was unknown.However, it was reported that the event occurred in 2020.All available information has been disclosed.If additional information should become available, a supplemental medwatch report will be submitted accordingly.
|
|
This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes, or its employees that the report constitutes an admission that the product, depuy synthes, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Device was used for treatment, not diagnosis.If information is obtained that was not available for this medwatch, a supplemental medwatch report will be filed as appropriate.Device evaluation: the actual device was returned for evaluation.During repair, an evaluation was performed, and it was determined that the battery housing cover had broken off and the markings on the housing were worn off, and various parts had been damaged and corroded.It was further determined that the device had a contact, seal, and a component damage, and the labeling was damaged, illegible and etched.It was observed that the device had a lid leak tightness test failure, corrosion/rusting/pitting, and a cracked/damaged housing.It was further determined that the device failed for general condition, marking and labeling, check the contacts, check battery casing cover and the lid and leakage test.Therefore, the reported condition was confirmed.The assignable root cause was determined to be traced to user, which is user error.If additional information should become available, a supplemental medwatch report will be submitted accordingly.
|