| Model Number |
7133 |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Code |
No Known Impact Or Consequence To Patient (2692)
|
| Date of Event |
06/01/2020
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Date of event: used the first date of the month of the aware date as no event date was provided.
|
| |
|
Event or Problem Description
|
|
It was reported that shaft break occurred.A 2.75mm x 15mm emerge balloon catheter was advanced for treatment.During an attempted angioplasty, the physician loaded device on wire and advanced through the guide to treat the vessel.About halfway through the guide, the catheter snapped in two.No further information was reported.
|
| |
|
Event or Problem Description
|
|
It was reported that shaft break occurred.A 2.75mm x 15mm emerge balloon catheter was advanced for treatment.During an attempted angioplasty, the physician loaded device on wire and advanced through the guide to treat the vessel.About halfway through the guide, the catheter snapped in two.No further information was reported.It was further reported that the device broke just outside the guide and the procedure was completed with another emerge balloon catheter.
|
| |
|
Additional Manufacturer Narrative
|
|
(b3) date of event: used the first date of the month of the aware date as no event date was provided.
|
| |
|
Event or Problem Description
|
|
It was reported that shaft break occurred.A 2.75mm x 15mm emerge balloon catheter was used for treatment.During an attempted angioplasty, the physician loaded device on wire and advanced thourgh the guide to treat the vessel.About halfway through the guide was advanced, the catheter snapped into two.No further information was reported.It was further reported that the device broke just outside the guide and the procedure was completed with another emerge balloon catheter.
|
| |
|
Additional Manufacturer Narrative
|
|
(b3) date of event: used the first date of the month of the aware date as no event date was provided.Device evaluated by mfr: returned device consisted of an emerge mr balloon catheter in two pieces.The balloon was tightly folded.Analysis of the tip, inner/outer shaft, hypotube and hub included microscopic and visual inspection.Inspection revealed a complete separation in the hypotube, and there were numerous kinks in the hypotube.The fracture faces were ovalized, as if kinked prior to separating.Inspection of the device found no other damage or defects.
|
| |
|