Model Number U128
Device Problems Signal Artifact/Noise (1036); Over-Sensing (1438); Impedance Problem (2950)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 05/20/2019
Event Type  malfunction  
Manufacturer Narrative
Additional information has been requested.If additional information is received, this report will be updated.
 
Event Description
It was reported that this cardiac resynchronization therapy pacemaker (crt-p) and a non boston scientific right atrial (ra) lead exhibited a history of noise, oversensing, inappropriate atrial tachy response (atr) episodes, and a lead safety switch (lss) due to out of range impedance measurements.The device had been reprogrammed at the time of the lss.More frequent episodes of ra noise were being observed more recently.Boston scientific technical services (ts) discussed troubleshooting and programming options with the health care professional (hcp).The device remains in service.No adverse patient effects were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VALITUDE X4 CRT-P
Type of Device
PULSE GENERATOR, PACEMAKER, IMPLANTABLE, WITH CARDIAC RESYNCHRONIZATION (CRT-P)
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
4100 hamline avenue north
saint paul MN 55112
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
cashel road
clonmel
EI  
Manufacturer Contact
timothy degroot
4100 hamline avenue north
saint paul, MN 55112
6515826168
MDR Report Key10255384
MDR Text Key198348640
Report Number2124215-2020-13380
Device Sequence Number1
Product Code NKE
UDI-Device Identifier00802526559402
UDI-Public00802526559402
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P030005/S113
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 07/09/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/09/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date02/08/2021
Device Model NumberU128
Device Catalogue NumberU128
Device Lot Number739657
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received06/25/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured02/21/2019
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age68 YR
-
-