MAUDE Adverse Event Report: MEDIVANCE, INC. ¿ 1725056 ARCTIC SUN TEMPERATURE MANAGEMENT SYSTEM, ARCTICGEL PADS; ARCTIC GEL PADS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDIVANCE, INC. ¿ 1725056 ARCTIC SUN TEMPERATURE MANAGEMENT SYSTEM, ARCTICGEL PADS; ARCTIC GEL PADS Back to Search Results
Catalog Number 318-02
Device Problems Defective Device (2588); Misassembly by Users (3133)
Patient Problems No Consequences Or Impact To Patient (2199); No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.
 
Event Description
It was reported that neonate started to rewarm around 530pm.Rewarm should have been complete at 1130pm but the timer reads 1 hour 40 minutes remaining.The baby was up to 35.6c at one time, but was down to 35.4c now in arctic sun device serial no: (b)(4).Patient was 35.5c.Rewarm tab read to rewarm from 36c to 36c at 0.4c/hr.Nurse confirms their protocol was to rewarm to 36c, she was not sure of rate but assumed 0.4c/hr is correct.Patient was currently 35.5c.Water 36.6c.Flow 0.8lpm.Ip -7psi, cp 27%.Nurse disconnected and reconnected the pad rotating the orientation of the clamp.Flow now was 1.1lpm.The straps were not around the abdomen.Mss asked nurse to secure the straps and "taco" the baby and mss suggested turning on radiant heat if their protocol allows and these measures are not successful.Trend was neutral at beginning of call, now pointing up.Temperature up to 35.6c.Confirmed the timer is counting up, not down.As per the follow up information, the nurse stated therapy completed and pads disposed of after use.
 
Manufacturer Narrative
The reported event confirmed as user related issue.The product was used for treatment but it was unknown whether the product had caused the reported failure as no sample was returned for evaluation.A potential root cause for this failure could be due to ¿'misconnection of supply and return lines.' the lot number was unknown; therefore, the device history record could not be reviewed.The instructions for use were found adequate and state the following: "indications for use the arctic sun® temperature management system is a thermal regulating system, indicated for monitoring and controlling patient temperature in adult and pediatric patients of all ages.Contraindications ¿ there are no known contraindications for the use of a non-invasive thermoregulatory system.¿ do not place the neonatal arcticgel¿ pad on skin that has signs of ulcerations, burns, hives or rash.¿ do not remove the fabric release liner of the neonatal arcticgel¿ pad and expose the hydrogel.¿ do not place the neonatal arcticgel¿ pad hydrogel on immature (non-keratinized) skin or premature babies.¿ while there are no known allergies to hydrogel materials, caution should be exercised with any patient with a history of skin allergies or sensitivities.Warning do not place the neonatal arcticgel¿ pad over transdermal medication patches as warming can increase drug delivery and cooling can reduce the drug delivery, resulting in possible harm to the patient.Cautions ¿ federal law restricts this device to sale by or on the order of a physician.¿ the neonatal arcticgel¿ pad is only for use with the arctic sun® temperature management system.¿ this product is to be used by or under the supervision of trained, qualified medical personnel.¿ the clinician is responsible for determining the appropriateness of use of this device and the usersettable parameters, including water temperature, for each patient.¿ due to underlying medical or physiological conditions, some patients are more susceptible to skin damage from pressure and heat or cold.Patients at risk include those with poor tissue perfusion or poor skin integrity due to edema, diabetes, peripheral vascular disease, poor nutritional status, steroid use, or high dose vasopressor therapy.If accessible, examine the patient¿s skin under the neonatal arcticgel¿ pad often; especially those patients at higher risk of skin injury.¿ skin injury may occur as a cumulative result of pressure, time and temperature.¿ possible skin injuries include bruising, tearing, skin ulcerations, blistering, and necrosis.¿ do not place bean bags or other firm positioning devices under the neonatal arcticgel¿ pad.¿ do not place any positioning devices under the pad manifolds or patient lines.¿ if warranted, use pressure relieving or pressure reducing devices under the patient to protect from skin injury.¿ do not allow urine, stool, antibacterial solutions or other agents to pool underneath the neonatal arcticgel¿ pad.Urine, stool and antibacterial agents can absorb into the pad hydrogel and cause chemical injury, skin irritation, and loss of pad adhesion over time.Replace pads immediately if these fluids come into contact with the hydrogel.¿ do not place the neonatal arcticgel¿ pad directly over an electrosurgical grounding pad.The combination of heat sources may result in skin burns.¿ if needed, place defibrillation pads between neonatal arcticgel¿ pad and the patient¿s skin.¿ the neonatal arcticgel¿ pad is non-sterile for single patient use only.¿ do not place pads in the sterile field.If used in a sterile environment, pads should be placed according to the physician¿s directions, either prior to the sterile preparation or sterile draping.¿ do not reprocess or sterilize.¿ use pads immediately after opening.¿ do not store pads in opened pouch.¿ the neonatal arcticgel¿ pad should not be punctured with sharp objects.Punctures will result in air entering the fluid pathway and may reduce performance.¿ the neonatal arcticgel¿ pad must be replaced after 120 hours (5 days) of use.¿ do not allow circulating water to contaminate the sterile field when lines are disconnected.¿ discard used neonatal arcticgel¿ pad in accordance with hospital procedures for medical waste.Directions 1.Place the patient (1.8 - 4.5 kg; 4.0 - 9.9 lb) on the pad.Avoid placing the patients over the manifolds or other high pressure locations.The rate of temperature change and potentially the final achievable temperature is affected by pad surface area coverage, placement, patient size, and water temperature range.2.The pad surface must be contacting the skin for optimal energy transfer efficiency.A) if desired, the center section of the pad can be wrapped around the patient¿s torso and secured in place using the velcro tabs provided.¿ if this option is in use, ensure that the edges of the pad are away from articulating areas of the body to avoid irritation.¿ place pads to allow for full respiratory excursion.(e.G.Ensure free movement of the chest and abdomen are guaranteed).¿ the pads may be removed and reapplied if necessary.¿ pads should be placed on healthy, clean skin only.3.Due to the small patient size (1.8 - 4.5 kg; 4.0 - 9.9 lb) and the potential for rapid patient temperature change, it is recommended to use the following settings to the arctic sun® temperature management system: ¿ water temperature high limit: =40°c (104°f) ¿ water temperature low limit: =10°c (50°f) ¿ control strategy: 2 4.Due to the small patient size (1.8 - 4.5 kg; 4.0 - 9.9 lb) it is recommended to use the patient temperature high and patient temperature low alert settings.5.Place a core patient temperature probe and connect to the arctic sun® temperature management system patient temperature 1 connector for continuous patient temperature feedback.A rectal or esophageal temperature probe is recommended.6.Verify patient core temperature with an independent temperature probe before and at regular intervals during use.7.Attach the pad¿s line connectors to the fluid delivery line manifolds.8.See arctic sun® temperature management system operators manual and help screens for detailed instructions on system use.9.Begin treating the patient.10.If the pad fails to prime or a significant continuous air leak is observed in the pad return line, check the connections, then if needed, replace the leaking pad.Once the pad is primed, assure the steady state flow rate displayed on the control panel is appropriate.The minimum flow rate should be 1.1 l/m.11.When finished, purge water from pad." h11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : the device was not returned.
 
Event Description
It was reported that neonate started to rewarm around 530pm.Rewarm should have been complete at 1130pm but the timer reads 1 hour 40 minutes remaining.The baby was up to 35.6c at one time, but was down to 35.4c now.S/n dybpy095 patient was 35.5c.Rewarm tab read to rewarm from 36c to 36c at 0.4c/hr.Nurse confirms their protocol was to rewarm to 36c, she was not sure of rate but assumed 0.4c/hr is correct.Patient was currently 35.5c.Water 36.6c.Flow 0.8lpm.Ip -7psi, cp 27%.Nurse disconnected and reconnected the pad rotating the orientation of the clamp.Flow now was 1.1lpm.The straps were not around the abdomen.Mss asked nurse to secure the straps and "taco" the baby and mss suggested turning on radiant heat if their protocol allows and these measures are not successful.Trend was neutral at beginning of call, now pointing up.Temperature up to 35.6c.Confirmed the timer is counting up, not down.As per the follow up information, the nurse stated therapy completed and pads disposed of after use.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARCTIC SUN TEMPERATURE MANAGEMENT SYSTEM, ARCTICGEL PADS
Type of Device
ARCTIC GEL PADS
Manufacturer (Section D)
MEDIVANCE, INC. ¿ 1725056
321 s taylor ave
louisville CO 80027
MDR Report Key10258299
MDR Text Key200613951
Report Number1018233-2020-04460
Device Sequence Number1
Product Code DWJ
Combination Product (y/n)N
PMA/PMN Number
K142702
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional,other,use
Type of Report Initial,Followup
Report Date 09/17/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/10/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number318-02
Was Device Available for Evaluation? No
Date Manufacturer Received08/26/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-