• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SPECTRANETICS ANGIOSCULPT PTA SCORING BALLOON CATHETER (OTW); CATHETER, PERCUTANEOUS, CUTTING/SCORING

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SPECTRANETICS ANGIOSCULPT PTA SCORING BALLOON CATHETER (OTW); CATHETER, PERCUTANEOUS, CUTTING/SCORING Back to Search Results
Model Number 2092-4040
Medical Device Problem Codes Material Rupture (1546); Improper or Incorrect Procedure or Method (2017)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 06/26/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The patient's age at time of event or dob, gender, and weight are unknown.This information was not available from the facility.During inflation, the balloon ruptured above rbp.Recurrence of this malfunction could result in a flow limiting dissection, embolism, or perforation.No patient injury reported.Cross reference mfr report numbers: 3005462046-2020-00014.Patient information regarding relevant tests/laboratory data or medical history are unknown.This information was not available from the facility.Report source: foreign- (b)(6).The angiosculpt device was infectious and discarded by the facility, thus no returned product investigation was performed.The angiosculpt device was used off-label.The ifu states to inflate the balloon 2 atm every 10-15 seconds until full balloon inflation is achieved and to not exceed the rbp printed on the package label.
 
Event or Problem Description
The angiosculpt device was used in a severely calcified popliteal, p2.The balloon was inflated quickly above the rated burst pressure (rbp) when the balloon ruptured.The user was aware that the device was used outside of the ifu.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ANGIOSCULPT PTA SCORING BALLOON CATHETER (OTW)
Common Device Name
CATHETER, PERCUTANEOUS, CUTTING/SCORING
Manufacturer (Section D)
SPECTRANETICS
5055 brandin court
fremont CA 94538
MDR Report Key10261496
Report Number3005462046-2020-00013
Device Sequence Number11529373
Product Code PNO
UDI-Device Identifier00813132021405
UDI-Public00813132021405
Combination Product (Y/N)Y
Initial Reporter CountryUK
PMA/510(K) Number
K100303
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 06/29/2020
Report Date (Section F) 01/01/2005
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/22/2022
Device Model Number2092-4040
Device Catalogue Number2092-4040
Device Lot NumberG19010027
Was Device Available for Evaluation? No
Was the Report Sent to FDA? Yes
Date Report to Manufacturer01/10/2005
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/29/2020
Initial Report FDA Received Date07/10/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Date Report Sent to FDA01/01/2005
-
-