Model Number N/A
Medical Device Problem Code Material Deformation (2976)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 06/23/2020
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Implanted date: device was not implanted.Explanted date: device was not explanted.The actual device has been returned for evaluation.The investigation is currently ongoing.A follow up report will be submitted once the investigation is complete.A review of the device history record of the product code/lot# combination was conducted with no findings.This report is for the second device reported, for the first device reported that was used on the same patient.See mdr 1118880-2020-00173.
 
Event or Problem Description
The user facility reported the destination device had multiple kinks/smashed.The patient condition was good.The outcome of the procedure was good.There was no patient injury, medical/surgical intervention required.Additional information was received on 26june2020: the type of the procedure was a peripheral leg case.The procedure was completed using another destination.
 
Additional Manufacturer Narrative
This report is being submitted as follow up no.1 to provide additional information to the b5 section, to update section h3, and to provide the completed investigation results.One used 6fr 65 cm destination sheath and dilator was received for product evaluation at terumo medical corporation.The dilator was not mated to the sheath when received.Visual inspection revealed one flattened segment was observed on the sheath.Measurements of the flattened segment was found to be starting at 37.5 cm and ending at 41.5 cm from the hub.No other visual anomalies were observed.Based on the provided information and investigation results, there is no definitive evidence that this event was related to a device defect or malfunction.However, the exact cause of the reported event cannot be definitively determined based on the available information.
 
Event or Problem Description
Additional information was received on 07august2020: when the wire was fed into the sheath during preparation, that was when they noticed the flattened portion.He took another sheath and found that it was also damaged.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DESTINATION PERIPHERAL GUIDING SHEATH
Common Device Name
INTRODUCER, CATHETER
Manufacturer (Section D)
TERUMO MEDICAL CORPORATION
950 elkton blvd.
elkton, md
MDR Report Key10292567
Report Number1118880-2020-00174
Device Sequence Number811763
Product Code DYB
UDI-Device Identifier00389701007786
UDI-Public00389701007786
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K172995
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 07/17/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/31/2022
Device Model NumberN/A
Device Catalogue NumberRSP01
Device Lot NumberXK21
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/06/2020
Initial Date Received by Manufacturer 06/24/2020
Supplement Date Received by Manufacturer08/07/2020
Initial Report FDA Received Date07/17/2020
Supplement Report FDA Received Date08/13/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-