Catalog Number UNK_KIE
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Discomfort (2330); Injury (2348); Non-union Bone Fracture (2369)
Event Date 06/12/2020
Event Type  Injury  
Manufacturer Narrative
The reported event could not be confirmed, since the device was not returned for evaluation and no other additional information is available.More detailed information about the complaint event as well as the affected device must be available in order to determine the root cause of the complaint event.The device history record could not be reviewed because the affected lot number was not communicated.If any further information is provided, the investigation report will be updated.Device disposition is unknown.
 
Event Description
The manufacturer became aware of a post market clinical follow-up report received from (b)(6) hospital, in usa.The title of this report is ¿a retrospective data collection of the treatment of the ankle with the t2 ankle arthrodesis nailing system¿ which is associated with the stryker ¿t2 ankle arthrodesis nailing¿ system.This report includes research done on 127 patients between the period april, 2019 and january, 2020.It was not possible to ascertain specific device details from the report, or to match the events reported with previously reported complaints.Therefore, new complaints were initiated in the system for the post-operative complications mentioned in the report.This product inquiry addresses discomfort over anterior tibia and ankle, cortical reaction in anterior tibia cortex and nonunion of the tibiotalar joint followed by nail removal with revision of tibitalar joint with another implant.The report states: ¿(b)(6) year old female with a past medical history of rheumatoid arthritis and coronary artery disease who initially underwent a right total ankle arthroplasty in 2010 which was converted to a tibiotalocalcaneal fusion with a stryker t2 ankle arthrodesis nail (10x200mm nail) secondary to progressive subtalar arthritis and cystic degeneration of the talus in (b)(6) 2017.She did well postoperatively however developed discomfort over the anterior tibia and ankle as well as a cortical reaction in the anterior tibial cortex.This was deemed secondary to a stress riser proximally from her nail.A ct scan was obtained in (b)(6) 2017 which was significant for fusion of the subtalar joint, however there appeared to be nonunion of the tibiotalar joint.She underwent intramedullary nail removal with revision tibiotalar fusion using another implant in (b)(6) 2017.¿.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN TALAR SCREW
Type of Device
IMPLANT
Manufacturer (Section D)
STRYKER TRAUMA KIEL
prof. kuentscher-strasse 1-5
schoenkirchen/kiel D-242 32
DE  D-24232
Manufacturer (Section G)
STRYKER TRAUMA KIEL
prof. kuentscher-strasse 1-5
schoenkirchen/kiel D-242 32
DE   D-24232
Manufacturer Contact
anna jusinski
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key10305517
MDR Text Key199927813
Report Number0009610622-2020-00354
Device Sequence Number1
Product Code HSB
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type study
Reporter Occupation Physician
Type of Report Initial
Report Date 07/21/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/21/2020
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Lay User/Patient
Device Catalogue NumberUNK_KIE
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received06/24/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age77 YR
-
-