MAUDE Adverse Event Report: DEPUY INTERNATIONAL LTD - 8010379 UNKNOWN HIP FEMORAL HEAD

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DEPUY INTERNATIONAL LTD - 8010379 UNKNOWN HIP FEMORAL HEAD Back to Search Results
Catalog Number UNK HIP FEMORAL HEAD
Device Problem Naturally Worn (2988)
Patient Problems Test Result (2695); No Code Available (3191)
Event Date 05/07/2018
Event Type  malfunction  
Manufacturer Narrative
(b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.(b)(4).
 
Event Description
The literature article entitled, "femoral offset found not to affect metal ion levels in metal-on-metal total hip arthroplasty" written by eoghan pomeroy, fergal macnamara, evelyn murphy, niall mcgoldrick, anant mahapatra, and nasir awan published by irish journal of medical science published online on 7 may 2018 was reviewed.The article's main purpose was to investigate the relationship between femoral offset and wear by measuring circulating metal ion levels in mom (metal-on-metal) in tha (total hip arthroplasty.Data was compiled from 95 patients (68 males and 27 females) with mean age of 64.9 years at time of surgery and all were implanted with depuy asr xl system implanted between december 2005 and august 2010.Femoral stem was not identified.The article does not report if any of the patients were revised or experienced any adverse symptoms.The article only reports the findings were elevated ion levels (attributed to bearing wear).The article did not report any statistically significant correlation between femoral offset groups and chromium ion levels.Depuy products: asr xl head, asr xl cup, asr xl sleeve (augment).Adverse events: elevated ion levels attributed to bearing wear.
 
Manufacturer Narrative
Product complaint # : (b)(4).Investigation summary: no device associated with this report was received for examination.A worldwide lot specific complaint database search, or device history record (dhr) review was not possible because the required lot code(s) was not provided.Based on previous investigations this complication of joint replacement is unlikely to have been the result of a device failing to meet required specifications.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Corrective action was not indicated.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN HIP FEMORAL HEAD
Type of Device
HIP FEMORAL HEAD
Manufacturer (Section D)
DEPUY INTERNATIONAL LTD - 8010379
st. anthony's road
leeds LS11 8DT
UK  LS11 8DT
MDR Report Key10306326
MDR Text Key200882589
Report Number1818910-2020-16488
Device Sequence Number1
Product Code KWY
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Remedial Action Recall
Type of Report Initial,Followup
Report Date 07/13/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/22/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberUNK HIP FEMORAL HEAD
Was Device Available for Evaluation? No
Date Manufacturer Received07/27/2020
Is This a Reprocessed and Reused Single-Use Device? No
Removal/Correction NumberZ-1749/1816-2011
Patient Sequence Number1
-
-