Model Number 55840006545
Medical Device Problem Code Break (1069)
Health Effect - Clinical Codes Pain (1994); No Known Impact Or Consequence To Patient (2692)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
Surgical history: infuse was used in the primary operation in 2019.Pre-op diagnosis: spinal stenosis procedure: navigated posterior spinal fusion levels implanted: s1 it was reported that on an unknown date, post-op, the screw was broken.Hence, the revision surgery was performed for replacement of screw and extending the fusion up to t9 for acute spinal stenosis.Patient had a primary spinal fusion from l3-s1 in 2019.One cage implanted at l3/4.Partial shaft of screw still inside the patient.Any complication to the patient was unknown.The complication is that the patient needed to have another operation in a very short time within one year of the primary surgery.She was complaining of pain down her right leg which is the side where the screw broke.
 
Additional Manufacturer Narrative
H3: product analysis #703861935:55840006545, lot# h5499285.Visual examination of the mas bone screw confirmed bone screw complete fracture at approximately 6 threads from the base of the bone screw head.Optical examination did not identify material defect near the area of fracture origin, which could contribute to crack propagation.Microscopic examination of the fracture surface identified gently curving convex striations through the cross-sectional area of the implant, which is indicative of cyclic fatigue until subsequent mechanical failure of the implant.D3: manufacturing site details updated.B1, b2, h1: updated for additional information.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CD HORIZON SPINAL SYSTEM
Common Device Name
APPLIANCE, FIXATION, SPINAL INTERLAMINAL
Manufacturer (Section D)
MDT SOFAMOR DANEK PUERTO RICO MFG
barrio marianna rd 909, km0.4
humacao,pr TN 00792
MDR Report Key10307688
Report Number1030489-2020-00954
Device Sequence Number803947
Product Code KWP
UDI-Device Identifier00613994971753
UDI-Public00613994971753
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K113174
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2019
Device Explanted Year2020
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 11/02/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number55840006545
Device Catalogue Number55840006545
Device Lot NumberH5499285
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/06/2020
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/21/2020
Supplement Date Received by Manufacturer10/17/2020
Initial Report FDA Received Date07/22/2020
Supplement Report FDA Received Date11/02/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age60 YR
Patient Weight68
-
-