| Model Number |
G22026 |
| Medical Device Problem Codes |
Fracture (1260); Dent in Material (2526)
|
| Health Effect - Clinical Codes |
No Known Impact Or Consequence To Patient (2692); No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
06/24/2020
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Investigation is still pending, a follow up mdr will be submitted to include the investigation conclusions.
|
| |
|
Event or Problem Description
|
|
Pigtail snap when adjusted to wire."as per complaint form": when they stretched the pigtail to insert the stent trough the scope, the pigtails snapped.Patient outcome: a section of the device did not remain inside the patient¿s body.The patient did not require any additional procedures due to this occurrence.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.Patient/event info - notes: please indicate where the device was stored prior to use.The device was stored in a cupboard.What is the reorder number, outer diameter and length of the wire guide that was used with this device in this procedure?* jagwire 0.035.Were previous procedures i.E.Sphincterotomy etc.Carried out prior to placing the device over the particular wire guide? if yes please indicate the procedure performed.Sphincterotomy was carried out.Was the wire guide inspected for damage prior to use? yes.Was the device at the centre of the complaint inspected for damage prior to use? yes.Did the patient involved exhibit altered anatomy or tortuous anatomy? no.If not with the device in question, how was the procedure finished?* with a other stent from the competitor.Is the patient known to be covid-19 positive? no.For complaints occurring during use (once in contact with endoscope) also ask: had a sphincterotomy been performed prior to this occurrence? yes.What is the endoscope manufacturer, the model number and working channel size that was used for the procedure? channel size 4.2; duodenoscope olympus.Does your medical facility have a service/maintenance schedule associated with its endoscopes? no.Please indicate the location in the body where the stent device was to be placed.I.E.Biliary duct, pancreatic duct, other.The stent snapped off before it could be placed.Was resistance encountered when advancing the wire guide to the target location?* no.Was the stricture dilated prior to placing the device?* if so, please indicate what device(s) were used.Not relevant to the complaint.Was resistance encountered when advancing the introduction system in place to the target location?*not relevant.Was resistance encountered when advancing the stent through the obstructed area?* n/a (mark n/a if device was not used on any patient).After placement, was stent position verified? if yes, please describe how.Please estimate/indicate the amount of time the stent was in place dwelling prior to this occurrence.N.A.Did any section of the device detach inside the endoscope or patient? no.If the device broke upon removal, please indicate what removal tool(s) were used (manufacturer).Please indicate any other endoscopic accessories (if any) that came into contact with the stent or introduction system during the procedure.Were any modifications made to the complaint device or accessories used with the device in this procedure? ¿ for example guiding catheter shortened.If so please indicate the modifications and why they were necessary.No.Not applicable if problem occurred at removal.
|
| |
|
Additional Manufacturer Narrative
|
|
Device evaluation: 1 x zebd-8-12 of lot # cf1684945 was returned to cirl for evaluation open in its original packaging.This file deals with the kink of the zebd-8-12 stent.This file is related to: (b)(4) (3001845648-2020-00446) - deals with the kink of the zso-8-10 stent in patient 1 (device #1 in lab evaluation for (b)(4)).(b)(4) (3001845648-2020-00455) - deals with the kink of the zso-8-10 stent in patent 2.(b)(4) (3001845648-2020-00497) - deals with the kink of the zso-10-12 stent.Lab evaluation: the device involved in the complaint was evaluated in the laboratory on 15th july 2020.On device #1 a severe kink was noted on the 3rd porthole on the non-tapered end pigtail.A 0.035¿ wireguide would not pass the kink on the device.The straightener was returned the wrong way around on the device.On device #2 slight kinks were noted on 2nd and 4th porthole and a severe kink on the 5th porthole on the tapered end of the device.Slight kinks were also noted on 2nd 3rd and 4th porthole and a severe kink on the 5th porthole on the non-tapered end of the device.A 0.035¿ wireguide would not pass the kink on the device and no straightener was returned with the device.On device #3 slight kinks were noted on 2nd 3rd and 4th porthole and a kink also on the 5th porthole on the tapered end of the device.A 0.035¿ wireguide would not pass the kink on the device.Note: although the lab evaluation was carried out for (b)(4), this evaluation applies to (b)(4) as the device in question was evaluated in the lab as part of (b)(4).Documents review including ifu review: prior to distribution all zebd-8-12 devices are subjected to visual and functional checks to ensure device integrity.These inspections and functional checks are outlined in internal procedures in place in cirl.A review of the manufacturing records for zebd-8-12 of lot number cf1684945 did not reveal any discrepancies that could have contributed to this complaint issue.The review of relevant manufacturing records confirms the failure mode has not previously occurred with the current lot number.Based on the information available to date, there is no evidence to suggest that there are any manufacturing issues associated with lot number cf1684945.The instructions for use, ifu0045-7 which accompanies this device instructs the user to ¿visually inspect with particular attention to kinks, bends and breaks.If an abnormality is detected that would prohibit proper working condition, do not use.¿ also, the user is instructed by the instructions for use, ifu0045-7: ¿care must be exercised when straightening the pigtail curls* in order to avoid kinking or breaking the stent.¿ it was noted that the straightener was used with the device and was not returned as it was disposed of afterwards.It was also noted that the stent became kinked when ¿the customer straightened the pigtails to insert the stent into the working channel¿.There is no evidence to suggest that the user did not follow the instructions for use.Root cause review: a definitive root cause cannot be determined, as the circumstances of use cannot be replicated in the laboratory and due to limited information.A possible cause of this complaint may be that the kink occurred while being straightened as it was being loaded onto the wire guide.Summary: complaint is confirmed as the failure was verified in the laboratory.According to the information reported, the patient did not experience any adverse effects due to this occurrence.Complaints of this nature will continue to be monitored for potential emerging trends.
|
| |
|
Event or Problem Description
|
|
Supplemental report is being submitted due to the completion of the investigation.
|
| |
|