Complainant part is expected to be returned for manufacturer review/investigation, but has yet to be received.Reporter is a synthes employee.The investigation could not be completed; no conclusion could be drawn, as no product was received.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.(b)(4).Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H3, h4, h6 investigation summary product was not returned.Based on the information available, it has been determined that no corrective and preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device history part number: 02.205.280, 5.0mm cannulated conical screw 80mm, lot number: 3l20230 (non-sterile), manufacturing location: monument , manufacturing date: 24-may-2019, lot quantity: 91.Four pieces were scrapped in cell at op #20, gundrill, after a functional failure.One piece was scrapped in cell at op #30, mill threads, after a machine malfunction.Production order traveler met all inspection acceptance criteria apart from the five pieces noted.Inspection sheet, inspect turn/wobble broach/inspect gun drill/inspect mill threads/inspect grind flutes/final inspection, met all inspection acceptance criteria apart from the four pieces noted.Packaging label log was reviewed and determined to be conforming.Packaging bom was reviewed and determined to be conforming with no deviations to normal packaging identified.This lot met all dimensional, visual and packaging criteria at the time of release with no issues documented during the manufacture that would contribute to this complaint condition.Component part(s) reviewed: part number: 11222, 316l**ri8.50, lot number: h728604, lot quantity: 1,844 lbs.Certificate of tests supplied by carpenter dated 20-aug-2018 was reviewed and determined to be conforming.Lot summary report dated 31-aug-2018 met all inspection acceptance criteria.Raw material receiving/putaway checklist met all inspection acceptance criteria.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|