BAXTER HEALTHCARE CORPORATION PRISMAFLEX M150; DIALYZER, HIGH PERMEABILITY WITH OR WITHOUT SEALED DIALYSATE SYSTEM Back to Search Results
Catalog Number 115307
Device Problems Fluid/Blood Leak (1250); Improper or Incorrect Procedure or Method (2017)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 07/01/2020
Event Type  malfunction  
Manufacturer Narrative
(b)(6).Should additional relevant information become available, a supplemental report will be submitted.
 
Event Description
It was reported that during treatment with a prismaflex m150 set, an external leak that ¿dripped to the floor¿ was observed from the drain bag.There was no report of patient injury or medical intervention associated with this event.No additional information is available.
 
Manufacturer Narrative
H10: the actual device was not available; however, a video of the sample was provided for evaluation.The visual inspection of the provided video revealed the leak to be coming from the level of the stopcock.The reported condition was verified.The cause was user error related.A batch review was conducted and there were no deviations found related to this reported condition during the manufacture of this lot.It is to be noted that the prismaflex m150 set ckt set and all the accessories provided within the set, including the drain bag, is a single use product.During the investigation of similar complaints, it has been noticed that the leakage on the drain bags occurred mainly after several hours of treatment where the bags were being filled and emptied several times.The filling/emptying cycles generates physical constraints on the bags, near the welding of the exhausting tube, eventually causing pinholes to form and leakage to happen.The prismaflex control unit warns the operator when the effluent bag is full and it is specified in the on-screen instruction delivered by the prismaflex control unit that the drain bag should be disconnected and changed for a new bag.Only one bag is provided within the sets since this bag is the one needed to prime the set and to start therapy.Spare bags have been made available in taiwan as of july 2020.A nonconformance has been opened to at the plant to address these reported complaints.Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PRISMAFLEX M150
Type of Device
DIALYZER, HIGH PERMEABILITY WITH OR WITHOUT SEALED DIALYSATE SYSTEM
Manufacturer (Section D)
BAXTER HEALTHCARE CORPORATION
deerfield IL
MDR Report Key10329231
MDR Text Key202360713
Report Number8010182-2020-00097
Device Sequence Number1
Product Code KDI
Combination Product (y/n)Y
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 08/14/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/27/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number115307
Device Lot Number20C1205
Was Device Available for Evaluation? No
Date Manufacturer Received08/04/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
NI.
-
-