|
OBERDORF SYNTHES PRODUKTIONS GMBH 2.4MM CORTEX SCREW SLF-TPNG WITH T8 STARDRIVE 16MM STERILE; SCREW, FIXATION, BONE
|
Back to Search Results |
|
| Model Number |
201.766TS |
| Medical Device Problem Code |
Device-Device Incompatibility (2919)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
If the information is unknown, not available or does not apply, the section/field of the form is left blank.Complainant part is not expected to be returned for manufacturer review/investigation.The investigation could not be completed; no conclusion could be drawn, as no product was received.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
Device report from synthes reports an event in (b)(6) as follows: it was reported the screw would not disengaged from the tube.It is unknown when the event occurred and if there was patient or procedural involvement.This is report 3 of 8 for (b)(4).This complaint is linked to (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H6: the device was received, the investigation could not be completed, and no conclusion could be drawn, as product is entering the complaint system.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Investigation site: cq zuchwil, selected flow: packaging.Visual inspection: the va locking screw was received with the reported condition that the inner tube did not disengage from outer tube.The inspection performed at cq zuchwil confirmed that after unscrewing the outer cap the entire inner tube (cap with holder and screw) is retained within the outer tube, preventing the screw from being removed and used.No further damage is visible.Summary: the complaint condition is confirmed as the inner tube is retained within the outer tube during disassembly preventing the screw from being removed and used.This production lot (6l34625) was manufactured in oct.2019 according to the specification.This lot met all dimensional, visual and packaging criteria at the time of release with no issues documented during the inspection or release of the product that would contribute to this complaint condition.Further investigation has shown that this production lot is part of the corrective and preventive action (capa) and part of the field safety notice.The root cause was identified during the performed capa evaluation (inadequately defined design of the inner tube & inner cap).All further investigations and actions will be documented within capa and hence the in the investigation flow listed remaining investigation steps are not required device history lot part number: 201.766ts, synthes lot number: 6l34625, manufacturing site: selzach, supplier: (b)(4), release to warehouse date: oct.22, 2019, expiry date: oct.01, 2024.Lot 6l34625 is part of capa, therefore no further investigation is required for this lot number as the investigation including root cause definition has already been performed under this capa.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Search Alerts/Recalls
|
|
|