Model Number 01.12.035
Health Effect - Clinical Code Bone Fracture(s) (1870)
Date of Event 07/16/2020
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Batch review performed on 22 july 2020: lot 155406: (b)(4) items manufactured and released on 20-jan-2016.Expiration date: 2021-01-11.No anomalies found related to the problem.To date, (b)(4) items of the same lot have been already sold without any similar reported event.Clinical evaluation: stem revision performed 2 years after primary double mobility cementless total hip arthroplasty in a (b)(6) year old patient.In the radiographic image provided the stem looks slightly undersized, but this may be due to the bone withdrawing from the stem: the postoperative radiograph was not supplied.A single anteroposterior radiographic projection does not allow, anyway, to evaluate possible undersizing.The fact that the stem had no ongrowth might also suggest that a silent infection process had taken place, preventing osteointegration to happen.The reason of this failure cannot be finally determined.Preliminary investigation: preliminary visual investigation highlight residual ha on the stem and bone residual.From the preliminary visual investigation it is not possible to determine the failure root cause.
 
Event or Problem Description
1 year and 10 months after primary surgery, revision surgery for suspected loosening of the stem.Stem, head and liner revised successfully.The stem come out easily, so the loosening is confirmed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
STEM: QUADRA-H CEMENTLESS, HA COATED LAT STEM SIZE 5
Common Device Name
HIP CEMENTLESS STEM
Manufacturer (Section D)
MEDACTA INTERNATIONAL SA
strada regina
castel san pietro, 6874, CHE
SZ  6874, CHE
MDR Report Key10389665
Report Number3005180920-2020-00495
Device Sequence Number2259353
Product Code JDI
UDI-Device Identifier07630030802171
UDI-Public07630030802171
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K082792
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2020
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 08/11/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Operator of Device No Information
Device Expiration Date01/11/2021
Device Model Number01.12.035
Device Catalogue Number01.12.035
Device Lot Number155406
Was Device Available for Evaluation? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/16/2020
Initial Report FDA Received Date08/11/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age74 YR
Patient Weight72
-
-