MAUDE Adverse Event Report: MPRI SPRINT QUATTRO SECURE MRI SURESCAN; DEFIBRILLATOR, AUTOMATIC IMPLANTABLE CARDIOVERTER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MPRI SPRINT QUATTRO SECURE MRI SURESCAN; DEFIBRILLATOR, AUTOMATIC IMPLANTABLE CARDIOVERTER Back to Search Results
Model Number 694758
Device Problem Over-Sensing (1438)
Patient Problems Chest Pain (1776); Complaint, Ill-Defined (2331)
Event Date 07/19/2020
Event Type  malfunction  
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event Description
It was reported that one day post-implant, the lead integrity alert (lia) was triggered for the right ventricular (rv) lead due to high rate non-sustained episodes and sensing integrity counter (sic).It was noted that the patient complained of chest pain and "jerking".The rv lead remains in use.No further patient complications have been reported as a result of this event.
 
Event Description
It was further reported that there was not a lead performance issue.Per cardiology the patient has a history of torsades and the arrhythmias noted were real and not due to any lead issue.It was also noted that the patient did not have diaphragmatic stimulation and that a cxr (chest x-ray) and threshold tests verified that the rv lead had not dislodged.
 
Manufacturer Narrative
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SPRINT QUATTRO SECURE MRI SURESCAN
Type of Device
DEFIBRILLATOR, AUTOMATIC IMPLANTABLE CARDIOVERTER
Manufacturer (Section D)
MPRI
road 149 km 56.3
villalba PR 00766
MDR Report Key10395416
MDR Text Key202520722
Report Number2649622-2020-15325
Device Sequence Number1
Product Code LWS
UDI-Device Identifier00643169692374
UDI-Public00643169692374
Combination Product (y/n)N
PMA/PMN Number
P920015
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 08/18/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date12/02/2021
Device Model Number694758
Device Catalogue Number694758
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 07/22/2020
Initial Date FDA Received08/12/2020
Supplement Dates Manufacturer Received08/12/2020
Supplement Dates FDA Received08/18/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
5076-45, LEAD / DDMB1D1, ICD; 5076-45, LEAD / DDMB1D1, ICD
Patient Age76 YR
Patient Weight81
-
-