Model Number 74023723
Medical Device Problem Code Patient Device Interaction Problem (4001)
Health Effect - Clinical Code Joint Dislocation (2374)
Date of Event 07/17/2020
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that, after a tka surgery had been performed, there was a dislocation.It is believed that the baseplate had been set with wrong degree.A revision surgery was performed to treat the adverse event.The journey ii xr baseplate sz 2 lt was exchanged.The patient outcome is unknown.
 
Additional Manufacturer Narrative
H3, h6: the device, used in treatment, was not returned for evaluation.Therefore, product analysis could not be performed at this time.So the reported event could not be confirmed.A medical investigation was conducted and confirms this complaint reports a tka revision due to dislocation.Per email communication, it is confirmed that he surgeon confirmed that the baseplate was set at the wrong degree during primary implantation.However, there the requested x-rays and surgical reports are not available.Therefore, no further assessment is able to be performed at this time.A complaint history review found related failures; this failure mode will be monitored for future complaints for any necessary corrective actions.A review of the manufacturing records did not reveal a manufacturing abnormality that could have caused or contributed to the reported incident.A review of risk management files and instructions for use found that the reported failure was documented appropriately.Possible causes could include but not limited to traumatic injury, patient anatomy or abnormal loading of limb.At this time, we have no reason to suspect that the product failed to meet any product specifications at the time of manufacture.Based on this investigation, the need for corrective action is not indicated.Without the actual product involved and/or device information, our investigation cannot proceed.If the device or new information is received in the future, this complaint can be re-opened.No further actions are being taken at this time.We consider this investigation closed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
JRNY II XR BASEPLATE SZ 2 LT
Common Device Name
PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POL/M/POL
Manufacturer (Section D)
SMITH & NEPHEW, INC.
1450 brooks rd.
memphis TN 38116
MDR Report Key10399876
Report Number1020279-2020-03899
Device Sequence Number2757791
Product Code JWH
UDI-Device Identifier00885556613047
UDI-Public00885556613047
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K152726
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2020
Device Explanted Year2020
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 06/22/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number74023723
Device Catalogue Number74022202
Device Lot Number18BSL0017A
Was Device Available for Evaluation? Yes
Initial Date Received by Manufacturer 07/17/2020
Supplement Date Received by Manufacturer06/19/2021
Initial Report FDA Received Date08/12/2020
Supplement Report FDA Received Date06/22/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
-
-