Model Number N/A
Medical Device Problem Codes Activation, Positioning or Separation Problem (2906); Activation Failure (3270)
Health Effect - Clinical Code Blood Loss (2597)
Date of Event 07/23/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Implanted date: device was not implanted.Explanted date: device was not explanted.Patient height: 6ft.The actual device was not returned for evaluation.The investigation is currently ongoing.A follow up report will be submitted once the investigation is complete.A review of the device history record of the product code/lot# combination was conducted with no findings.This report is for the second device reported, for the first device reported that was used on the same patient see mdr 3013394970-2020-00496.
 
Event or Problem Description
The user facility reported that the involved angio-seal device was stuck in the angio-seal sheath.The angio-seal came all the way out.The estimated blood loss was less than 250cc's.The patient's condition was stable, no issues.There was no patient injury, medical/surgical intervention required.There were no other devices or equipment used with the reported product.Additional information was received on 27jul2020.Both occurrences happened on the same patient.The procedure was peripheral angiogram with intervention using a 7fr sheath.There was difficulty advancing the angio-seal through the angio-seal sheath; it was stuck in the proximal portion of the sheath and removed by using a hemostat.A pre- deployment angio was performed.Manual pressure was used, and hemostasis was achieved.No issues with the patient were noted from the angio-seal.When the first device failed, the second angio seal device was pulled.When the second device failed, manual compression was applied to achieve hemostasis.There were no issues with the patient noted from the angio-seal device.
 
Additional Manufacturer Narrative
This report is being submitted as follow up no.1 to provide the completed investigation results.The actual device was not returned; therefore, an evaluation of the actual device was unable to be conducted.With no return of the actual device, the exact cause of the reported event cannot be definitively determined based on the available information.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
6FR ANGIO-SEAL STS PLUS VASCULAR CLOSURE DEVICE, US
Common Device Name
DEVICE, HEMOSTASIS, VASCULAR
Manufacturer (Section D)
TERUMO MEDICAL CORPORATION
265 davidson ave
suite 320
somerset, nj
MDR Report Key10401220
Report Number3013394970-2020-00497
Device Sequence Number19546683
Product Code MGB
UDI-Device Identifier00389701011868
UDI-Public00389701011868
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
P930038
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 08/13/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/31/2020
Device Model NumberN/A
Device Catalogue Number610119
Device Lot Number06098315
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 07/24/2020
Supplement Date Received by Manufacturer09/08/2020
Initial Report FDA Received Date08/13/2020
Supplement Report FDA Received Date09/09/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age65 YR
Patient Weight127
-
-