SMITH & NEPHEW, INC. LGN PS HIGH FLEX XLPE SZ 3-4 13MM; PRSTHSS,KNEE,PTLLFMRTBIAL,SM-CNSTRAIND,CMNTD,POLYMER/MTL/POLYMER
|
Back to Search Results |
|
| Model Number |
71453213 |
| Medical Device Problem Code |
Malposition of Device (2616)
|
| Health Effect - Clinical Code |
Injury (2348)
|
| Date of Event |
07/23/2020
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that a revision of left tkr was performed due to patient presenting with pain with slight malalignment/malrotation of implant components.Primary left tkr was performed on (b)(6) 2017.During revision surgery the legion posterior stabilized high flex highly cross linked polyethylene was removed with renovation knee gear.Original oval 32mm patella was retained by surgeon.Bony canals and surfaces were prepped for a 5 left legion revision femur, 3 left revision tibia with tibial and femoral stems used with offset couplers and augmented femoral component.The components were trialled with rom check before implantation.The component implants used were cemented in with palacos cement and constrained 3-4 18mm insert implanted after cement curing.The wound was washed and irrigated, and betadine/saline soaked, and then closed in layers as per standard technique.
|
| |
|
Additional Manufacturer Narrative
|
|
It was reported that a revision of left tkr was performed due to patient presenting with pain with slight malalignment/malrotation of implant components.The affected complaint device, used in treatment, was not returned for evaluation.Therefore a product analysis could not be performed.A review of the complaint history on the listed part revealed no prior complaints for the listed failure mode with the same batch number.A review of the manufacturing records for the listed batch did not reveal any deviation from the standard manufacturing processes.At this time, we have no reason to suspect that the product failed to meet any product specifications at the time of manufacture.A relationship, if any, between the device and the reported incident could not be corroborated.A review of risk management files and the instructions for use found that the reported failure was documented appropriately.Based on this investigation, the need for corrective action is not indicated.No medical documents were received for investigation.Therefore no medical assessment can be performed at this time.Some potential causes of the reported event could include but are not limited to improper size of device used, unclear user instructions or user/procedural variance.No further investigation is warranted for this complaint; however we will continue to monitor for future complaints and investigate as necessary.Should additional information be received, the complaint will be reopened.We consider this investigation closed.
|
| |
|
Search Alerts/Recalls
|
|
|