Model Number 189628
Medical Device Problem Codes Break (1069); Crack (1135); Material Twisted/Bent (2981); Insufficient Device Problem Information (3190)
Health Effect - Clinical Codes Foreign Body In Patient (2687); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 07/21/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The manufacturer's investigation is on-going and further information will be provided once the investigation has been completed.
 
Event or Problem Description
The customer reported that a proguide obturator was broken in the patient body.
 
Additional Manufacturer Narrative
B1 updated information b3 added date.D9 updated information.H3 updated information.H6 updated coding.H7 new information.H10 added information.The investigation was completed by conducting a thorough evaluation of the product and the reported information.During the needle insertion for prostate treatment, a proguide obturator broke outside the patient.In addition, one proguide obturator was bent.A detailed analysis of the broken obturator regarding the material structure and chemical composition did not show any deviation or difference with sample material.Bending tests on sample material resulted in similar breakage patterns as in the returned obturator.Based on these test results, the root cause of the breakage was determined to be excessive lateral force during handling and insertion of the obturators.When large bending forces are applied on the obturators, cracks can appear, from which the obturators can break.In this case, the user used excessive (lateral) force on the obturator during needle insertion, which resulted in the obturator to break (outside the patient's body).Excessive lateral forces should be avoided during the handling of obturators.The broken obturator was replaced.This event is caused by use error and is considered as accidental.There was no injury to the patient.Elekta assessed the severity of risk to be non-serious.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MICROSELECTRON
Common Device Name
SYSTEM, APPLICATOR, RADIONUCLIDE, REMOTE-CONTROLLED
Manufacturer (Section D)
NUCLETRON B.V.
waardgelder 1
veenendaal 3905 TH
NL  3905 TH
MDR Report Key10419385
Report Number9611894-2020-00003
Device Sequence Number2975864
Product Code JAQ
UDI-Device Identifier08717213051140
UDI-Public08717213051140
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K060349
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source foreign,other,user facility
Initial Reporter Occupation Non-Healthcare Professional
Remedial Action Replace
Type of Report Initial,Followup
Report Date (Section B) 02/19/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number189628
Device Lot Number1000156940
Was Device Available for Evaluation? Yes
Initial Date Received by Manufacturer 07/22/2020
Supplement Date Received by Manufacturer07/22/2020
Initial Report FDA Received Date08/18/2020
Supplement Report FDA Received Date02/19/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-