Catalog Number 1128350-38
Device Problem Activation Failure (3270)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 08/01/2020
Event Type  malfunction  
Manufacturer Narrative
The device is expected to be returned for investigation.It has not yet been received.A follow-up report will be submitted with all additional relevant information.
 
Event Description
It was reported that during the procedure, the 3.5x38 mm xience proa balloon could not be inflated to be deploy the stent in the target lesion.No resistance was noted during advancement.The stent delivery system was removed and the procedure was completed with another xience stent.There were no adverse patient effects and there was no reported clinically significant delay in the procedure.The physician could not remember if the device had been prepped correctly.No additional information was provided.
 
Manufacturer Narrative
B3, b6: dates were estimated.The device was returned for analysis.The reported activation failure including expansion failures/difficult to deploy was able to be confirmed.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history identified no other incidents from this lot.As there was no report of a leak during preparation for use, the investigation determined the reported difficulties appear to be related to circumstances of the procedure as it is likely that inadvertent mishandling/over torqueing during connection to the inflation device resulted in the noted longitudinal crack on the proximal end of the hub; thus resulting in the reported activation failure including expansion failures.There is no indication of a product quality issue with respect to manufacture, design or labeling.D4: expiration date.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
XIENCE PROA
Type of Device
DRUG ELUTING CORONARY STENT DELIVERY SYSTEM
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
MDR Report Key10443091
MDR Text Key204041912
Report Number2024168-2020-07034
Device Sequence Number1
Product Code NIQ
Combination Product (y/n)Y
PMA/PMN Number
P110019
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 10/22/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/24/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date06/01/2023
Device Catalogue Number1128350-38
Device Lot Number0052241
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/27/2020
Date Manufacturer Received09/28/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-