| Model Number |
M00573080 |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
07/31/2020
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Patient's exact age is unknown; however it was reported that the patient was over the age of 18.(b)(4).The device has been received for analysis; however, the analysis has not yet been completed.Upon completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental medwatch will be filed.
|
| |
|
Event or Problem Description
|
|
It was reported to boston scientific corporation that a jagtome rx 39 was used in the common bile duct (cbd) during an endoscopic retrograde cholangiopancreatography (ercp) procedure performed on (b)(6) 2020.According to the complainant, during the procedure, the cutting wire broke.Reportedly, no part of the device was detached inside the patient.The procedure was completed with another of the same device.There were no patient complications reported as a result of this event.
|
| |
|
Event or Problem Description
|
|
It was reported to boston scientific corporation that a jagtome rx 39 was used in the common bile duct (cbd) during an endoscopic retrograde cholangiopancreatography (ercp) procedure performed on (b)(6) 2020.According to the complainant, during the procedure, the cutting wire broke.Reportedly, no part of the device was detached inside the patient.The procedure was completed with another of the same device.There were no patient complications reported as a result of this event.
|
| |
|
Additional Manufacturer Narrative
|
|
Block a2: patient's exact age is unknown; however it was reported that the patient was over the age of 18.Block h6 (device codes): the problem code 1069 captures the reportable event of cutting wire broken.Block h10: the returned jagtome rx 39 was analyzed, and a visual evaluation noted that the cutting wire was detached, bent and blackened.Additionally, the device was observed under magnification that the cut of the cutting wire was not smooth.A functional evaluation could not be performed due to the condition of the device.No other issues with the device were noted.The reported event was confirmed.The failure found could had been generated if the device was not completely in contact with the tissue during energization or if the voltage exceeded the maximum voltage rating.Based on all gathered information, the most probable root cause of this complaint is adverse event related to procedure.A review of the manufacturing documentation for this device revealed that no anomalies or deviations related to the event occurred during manufacturing.A labeling review was performed and, from the information available, this device was used per the directions for use (dfu) / product label.
|
| |
|