Model Number PCO15X |
Device Problems
Adverse Event Without Identified Device or Use Problem (2993); Patient Device Interaction Problem (4001)
|
Patient Problems
Wound Dehiscence (1154); Abdominal Pain (1685); Adhesion(s) (1695); Erosion (1750); Unspecified Infection (1930); Inflammation (1932); Muscle Weakness (1967); Necrosis (1971); Pain (1994); Scar Tissue (2060); Skin Discoloration (2074); Hernia (2240); Discomfort (2330); Injury (2348); Impaired Healing (2378); Obstruction/Occlusion (2422); Ascites (2596); Abdominal Distention (2601); Unspecified Tissue Injury (4559); Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available (4581)
|
Event Type
Injury
|
Manufacturer Narrative
|
If information is provided in the future, a supplemental report will be issued.
|
|
Event Description
|
The patient¿s attorney alleged a deficiency against the device.The product was used for therapeutic treatment of a ventral incisional hernia.It was reported that after implant, the patient experienced abdominal pain, recurrence, adhesions, mesh erosion, and dehiscence.Post-operative patient treatment included exploratory laparotomy, lysis of adhesions, recurrent hernia repair, component separation, and mesh removal.
|
|
Event Description
|
The patient¿s attorney alleged a deficiency against the device.The product was used for therapeutic treatment of a ventral incisional hernia.It was reported that after implant, the patient experienced abdominal pain, recurrence, adhesions, mesh erosion, pain, infection, inflammation, necrosis, wound care, fluid build up, scarring, and dehiscence.Post-operative patient treatment included exploratory laparotomy, lysis of adhesions, recurrent hernia repair, component separation, blake drains, medication, mesh revision, debridement, wound vac, and mesh removal.
|
|
Manufacturer Narrative
|
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|
Manufacturer Narrative
|
Additional information: a2 (patient dob), a3, a4, b2, b5, b6, b7, h6 (added patient and imf codes) ime 2402: fiboradipose tissue medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|
Event Description
|
The patient¿s attorney alleged a deficiency against the device.The product was used for laparoscopic therapeutic treatment of a ventral hernia.It was reported that after implant, the patient experienced abdominal pain, recurrence, adhesions, mesh erosion, pain, infection, inflammation, necrosis, fluid build up, scarring, weak fascia, protuberance to the abdomen, distention, discomfort, diastasis, pink hue to skin, obstruction, fibroadipose tissue, and dehiscence.Post-operative patient treatment included exploratory laparotomy, lysis of adhesions, recurrent hernia repair with new mesh, component separation, mesh revision, medication, prolonged hospitalization, debridement of necrotic tissue, wound vac placed and removed, drains placed and removed, and mesh removal.
|
|