• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION GLADIATOR ELITE; CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION GLADIATOR ELITE; CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL Back to Search Results
Model Number 24686
Medical Device Problem Code Material Rupture (1546)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 08/20/2020
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that balloon rupture occurred.A 5.0 x40, 40cm gladiator balloon catheter was advanced for dilation.However, during inflation at 12 atmospheres, the balloon ruptured.The procedure was completed with another of the same device.No patient complications were reported and the patient was fine.
 
Event or Problem Description
It was reported that balloon rupture occurred.A 5.0 x40, 40cm gladiator balloon catheter was advanced for dilation.However, during inflation at 12 atmospheres, the balloon ruptured.The procedure was completed with another of the same device.No patient complications were reported and the patient was fine.
 
Additional Manufacturer Narrative
Device evaluated by mfr.:gladiator elite 5.0 x40, 40cm was returned for analysis.A visual examination identified that the balloon wings had been subjected to positive pressure.The returned device was attached to a boston scientific encore inflation unit and positive pressure was applied; the balloon was inflated to its rate of burst pressure and pressure held for 30 seconds without issue.A vacuum was then applied.The inflation device was verified at 24 atmospheres, before and after use.This inflation to rate of burst pressure of 24 atmospheres was repeated three times with no leaks or drop in pressure noted.No issues were identified with balloon inflation or the balloon material.A visual and microscopic examination observed no damage to the tip of the device.A visual and tactile examination of the shaft of the device found no issues.A visual examination found no issues or damage to the markerbands of the device.No other issues were identified during the product analysis.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GLADIATOR ELITE
Common Device Name
CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key10475024
Report Number2134265-2020-12021
Device Sequence Number2809275
Product Code LIT
UDI-Device Identifier08714729809661
UDI-Public08714729809661
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
K132810
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 10/15/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date11/03/2022
Device Model Number24686
Device Catalogue Number24686
Device Lot Number0024710764
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/14/2020
Initial Date Received by Manufacturer 08/20/2020
Supplement Date Received by Manufacturer10/02/2020
Initial Report FDA Received Date08/31/2020
Supplement Report FDA Received Date10/15/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-