MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION IMAGER II ANGIOGRAPHIC CATHETER; CATHETER, INTRAVASCULAR, DIAGNOSTIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION IMAGER II ANGIOGRAPHIC CATHETER; CATHETER, INTRAVASCULAR, DIAGNOSTIC Back to Search Results
Model Number 38270
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Patient Involvement (2645)
Date of Event 07/16/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Device evaluated by manufacturer: returned product consisted of an imager diagnostic catheter in the un-opened sterile pouch.Visual examination revealed that a kink was present located 26cm from the strain relief.The device was functionally tested with a test guidewire.The guidewire was inserted into the lumen from the hub end of the device and the guidewire transcended through the lumen until it reached approximately 2.5cm from the tip and the tip separated from the shaft.Inspection of the remainder of the device, apart from the observed damage, revealed no other damage or irregularities.
 
Event or Problem Description
An unused 5f contra imager ii angiographic catheter in it's unopened original packaging was returned to boston scientific from a customer.There was no reported complaint against this returned device.The device was intact upon receipt.Boston scientific carried out functional testing on the returned device which resulted in a tip detachment.This event is associated with previously reported field action 92484513-fa with product being removed from the field.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
IMAGER II ANGIOGRAPHIC CATHETER
Common Device Name
CATHETER, INTRAVASCULAR, DIAGNOSTIC
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key10475944
Report Number2134265-2020-11766
Device Sequence Number16881352
Product Code DQO
UDI-Device Identifier08714729355403
UDI-Public08714729355403
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K121694
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other
Remedial Action Recall
Type of Report Initial
Report Date (Section B) 09/01/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/13/2020
Device Model Number38270
Device Catalogue Number38270
Device Lot Number0000134631
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/16/2020
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 08/04/2020
Initial Report FDA Received Date09/01/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
If action reported to FDA under 21 USC 360i(g), list
FDA-assigned Recall Number or include a statement
92484513-FA
Patient Sequence Number1
-
-